Appliance type
Table ventilation
Table ventilation
Stainless steel
AL 400 121
AL 400 191
Air extraction / air recirculation
•/•
•/•
Compatible with (air extraction):
2x AR 400 142 / 2x AR 401 142 /
2x AR 403 122
AR 400 142 / AR 401 142 /
AR 403 122
Compatible with (air recirculation):
2x AR 413 122 / 2x AR 410 110
AR 413 122
Dimensions
Height of overall frame
(cm) 0.3
0.3
Surface mounting / flush mounting
•/•
•/•
Extending height
(cm) 33
33
Width on worktop
(cm) 118.4
90.8
Width in lower cabinet
(cm) 113.6
86
Depth on worktop
(cm) 14
14
Height in lower cabinet surface mounting / flush mounting
(cm) 55–86
55–86
Net weight
(kg) 46
38
Consumption data according to EU regulation 65 / 2014
Energy efficiency class
A²
Energy consumption
kWh/year
45.5²
Ventilation efficiency class
A²
Illumination efficiency class
E²
Grease filter efficiency class
C²
Sound level min. / max. normal mode
dB(A)
45/61²
Air extraction performance (EN 61591) with fan units, power level 1 / 2 / 3 / Intensive
with 2 remote fan units
with 2 ducts
Air extraction with AR 400 142 for inside installation
(m³/h) 540/820/1020/1140
310/485/600/765
Air extraction with AR 401 142 for outside wall mounting
(m³/h) 550/800/1000/1200
295/450/560/660
Air extraction with AR 403 122 for plinth installation
(m³/h) 560/750/980/1240
300/460/530/660
Air recirculation with AR 413 122 for plinth installation
(m³/h) 610/845/1080/1375
310/425/555/715
Air recirculation with AR 410 110 for cupboard installation
(m³/h) 740/890/1015/1210
Features
Extendable ventilation unit
•
•
Power levels
3 plus intensive
3 plus intensive
Automatic function
–
–
Run-on function
(min) •/6 min.
•/6 min.
Interval ventilation
(min) •/6 min.
•/6 min.
Grease filter saturation indicator
•
•
Grease filter art
Cartridge-type filter
Cartridge-type filter
Grease filter units
3
2
Grease drain channel
•
•
Art of lighting
LED
LED
Lamp output
(W) 4 x 5
4 x 5
Illuminance
(lx) 191
191
Lighting colour
(Kelvin) 3600
3600
Exhaust air connection bottom / side / top / back
•/–/•
•/–/•
Exhaust air connection piece DN 150 cylindrical duct
AD 754 045¹
AD 754 045¹
Exhaust air connection piece DN 150 flat duct
AD 854 045¹,
AD 854 045¹,
AD 854 043¹
AD 854 043¹
Connecting cable length
(m) 1.75
1.75
Connection
Total connected load
(W) depending on fan unit
depending on fan unit
Radio frequency interference-suppressed
•
•
• Standard. – Not available.
¹ Special accessory.
² Values refers to the configuration AL 400 with the remote fan unit AR 400 142.
³ Values refers to the configuration VL 414 with the remote fan unit AR 403 122.
Table ventilations 400 series