TRY
TRX T5
2x35 W HF REGLETTE
TRY LED
2A/M 25W 830
0,8
0,9
76 W
25 W
45%
45%
50%
50%
65%
65%
5776 W
1900 W
587 lx
556 lx
0,87
0,92
592 lx
549 lx
0,53
0,67
n. 76
AxB
25x2 m
h1
3,25 m
h2
2,2 m
54 - NEWS SPRING | 2019
TRY allows sensible cost reductions on both working and maintenance scenarios still granting high levels of lighting performance.
The payback is quickly reached and maintained thanks to the fixture’s long lifetime.
Here below, two examples of installation that compare a shopping mall.
QUICK PAYBACK
Quantity of luminaires
Dimensioni corsia
Installation height
Shelf height
Maintenance coefficient
Absorption [W] (driver included)
Reflection [Ro]
Floor
Wall
Ceiling
Results on aisle
Total consumption (driver included) [W]
Ēm - medium lighting [lx]
U0 (Emin/Ēm) - general uniformity [lx]
Results on shelf
Ēm - medium lighting [lx]
U0 (Emin/Ēm) - general uniformity [lx]
GENERAL STORAGE RACK AREAS INSIDE BUILDINGS
B
A
h2
h1
67%
-3876 W
ENERGY
SAVING