54
505 Up - System Manual
20. External lighting bars for suspended compositions
Barre illuminanti esterne per composizioni sospese
Lighting bars can be mounted only on the lower
part of the composition assembled.
Depending on the dimensions of the composition,
our Technical Office will calculate the dimensions
of the bar, which will always be in a single piece
(for compositions from 1312 to 2912). We advise
mounting the bar on suspended compositions
at a height from the ground that is not visible,
because in the lower part, a box will be installed to
contain the power supply units (see example) and
wiring will always be external. External lighting
bars function with the same power supply unit
and connector as the bars for the compartment
interior. It is possible to set up a single
system for internal and external lighting bars.
Le barre illuminanti possono essere applicate solo
nella parte inferiore a composizione montata. In
base alla dimensione della composizione il ns. Ufficio
Tecnico calcolerà la dimensione della barra, che sarà
sempre in un unico pezzo (per composizioni da 1312
a 2912). Si consiglia l’applicazione su composizioni
sospese ad altezza da terra non in vista in quanto
nella parte inferiore verrà collocata una scatola per
contenere gli alimentatori (vedi esempio) e i fili di
collegamento saranno esterni. Le barre illuminanti
esterne funzionano con lo stesso alimentatore e
connettore delle barre per vano interno. È possibile
realizzare un unico impianto per barre illuminanti
interne ed esterne.
=
=
electrical system box
contenitore impianto elettrico
30
30
10
75
303
172
lighting bar
barra illuminante
lighting bar
barra illuminante
corner joining filler
fasce di congiunzione ad angolo
vertical and horizontal filler th mm 20
fasce di chiusura verticali ed orizzontali Sp 20
260
2961
260
2961
2001
2385
2769
2961
side
spalla
side
spalla
70
22
22
70
•
matt lacquer colours
•
woods
•
glossy lacquer colours
•
laccato opaco colori
•
essenze
•
laccato lucido colori
FINISHES
FINITURE
When placing the order, the client must
indicate on the drawing the shelf or shelves
where the lighting bars are to be placed.
The bars cannot be mounted on two-sided
compositions, corner elements and open
corner elements. 3000 K warm light
All’atto dell’ordine il cliente deve indicare
sul disegno il piano o i piani dove desidera
le barre illuminanti. Le barre non possono
essere montate su composizioni bifacciali,
nell’elemento angolare e nelle composizioni a
giorno ad angolo. 3000 K luce calda
NOTES
NOTE