Installation notes for SmartLine
Checklist for the installation of SmartLine elements:
• Induction wok cannot be installed on the same side of the
countertop extractor as the vapour outlet
• When a countertop extractor is positioned between two gas
elements, the discharge direction can only be to the right
• Minimum depth of worktop for discharge direction to the right
(prepared at the factory) is 600 mm
• Minimum depth of worktop for discharge direction to the left is
665 mm
• Air discharge collar of the plinth fan is designed for flat ducting
(222 x 89 mm)
• Ducting system from countertop extractor to the plinth fan is
supplied with the appliance
• We recommend Miele’s flat ducting system to extend the ducting
system
• We advise against highly flexible ducting
• The countertop extractor’s electrical wires must not be extended
or altered. They have been certified as a fixed part of the appliance
only. Non-compliance will void the warranty
• Removable drip tray for the countertop extractor must be
accessible.
• Cable protection panel must be reversible
• Different casing depths of SmartLine elements must be observed
• When installing several SmartLine elements, an additional
CSZL 7000 spacer bar must be fitted in between the individual
elements
• Observe fixed panel
• For maintenance work it must be possible to remove the rear
cabinet wall
• Minimum plinth height for plinth fan is 100 mm
• Miele recommends the DUU 1000-1 recirculation box for
recirculation
• Only 1 countertop extractor can be connected per recirculation
box
• If possible, the recirculation box should discharge the air into free
space and it should be sufficiently far away from walls, cabinets or
other furniture
• The exhaust air from several countertop extractors should be
vented into atmosphere via separate vent paths
• Some installation situations may require the plinth feet to be moved