LUCEPLAN 2020
MOD.
110
LUCEPLAN 2020
MOD.
Diade
Diade
Acoustic solution
Acoustic solution
MOD.
Diade
Model of application
call center
Location analysis
A workspace where several people speaking need physical
isolation to be concentrated, sensible control of sound propagation + effective
control of light too.
Solution
Diade is a perfect solution that brings the sound control where needed, guaran-
tying pleasant light and anti-glare effect on working areas.
Room data
L = 49.2 ft
W = 32.8 ft
H = 13 ft
Fixtures installation
1 x Diade every 4 positions
7.9 ft from the ground
Lighting source used
LED module 45W (uplight)
LED module 35W (downlight)
Illuminance average
Post (average value) 44.6 fc
Before
Time of reverberation* 2,27 s
After
(+ 12 Diade)
Time of reverberation 1,33 s
Decrease of reverberation
about 41%**
* Measuring reverberation time allows to calculate total sound
absorption. Reverberation time varies according to the frequency.
If reverberation time is too long, the space can have echoes and
rumbles.
** The data is always approximate: the software doesn’t take in
consideration the position of the speaker and the position of absorbent
surfaces.
1
2
3
APPLICATION
Acoustic solution
PET
Sound Absorbing Panel
Extruded Aluminum Profile
LED strip
availailable also with uplight
(only in the horizontal configuration)
Acoustic calculation
AFF 7.9 ft
111