955
...m
Degree of protection
Classification of fittings
Colours
The resistance offered by the fixture
to the penetration of solids and
liquids is indicated by the IP prefix
(International Protection) followed
by two numbers. The first number
identifies the degree of protection
against the ingress of solids and the
second number against liquids (IEC
529 - EN 60529 publication).
The letters IK indicate the level of
shock resistance of the luminaire,
according to CEI EN 50102.
FIRST IDENTIFICATION NUMBER
Degree of protection against
penetration of solids.
0
Not protected
1
Protected against
penetration of solids
larger than 50 mm.
2
Protected against
penetration of solids
larger than 12 mm.
3
Protected against
penetration of solids
larger than 2.5 mm.
4
Protected against the
penetration of solids
larger than 1 mm.
5
Protected against the
penetration of dust
6
Completely protected
against penetration of
dust
SECOND IDENTIFICATION NUMBER
Degree of protection against
penetration of liquids.
0
Not protected
1
Protected against the
vertical fall of water
drops
2
Protected against the fall
of water at a maximum
angle of 15°
3
Protected against rain
4
Protected against
splashes
5
Protected against jets of
water
6
Protected against waves
7
Protected against the
effects of immersion
8
Protected against the
effects of prolonged
immersion
LEVEL OF SHOCK RESISTANCE
It designates the level of shock re-
sistance according to CEI EN 50102.
IK00
Not protected
IK01
Protected against 0.15
J shocks
IK02
Protected against 0.2 J
shocks
IK03
Protected against 0.35
J shocks
IK04
Protected against 0.5 J
shocks
IK05
Protected against 0.7 J
shocks
IK06
Protected against 1 J
shocks
IK07
Protected against 2 J
shocks
IK08
Protected against 5 J
shocks
IK09
Protected against 10 J
shocks
IK10
Protected against 20 J
shocks
Classification of fittings
according to electrical protection.
Class I
With functional insulation
in every part and with
earth terminal or clamp
if the unit is fixed, or with
electric power supply
cable complete with
earth wires and relative
plug with earth contact if
the unit is mobile.
Class II
With double insulation
and/or reinforced
insulation in every
part and without earth
connections.
Classification of fittings
according to the flammability of
the surfaces used for installation.
The fitting can be
installed on normally
flammable surfaces.
Class III products: performances
are assured only when using the
electronic power supply units and
drivers indicated in the catalogue.
Class III
Designed for connecting
to low voltage circuits,
without any internal
or external circuit
functioning at a voltage
different from safety low
voltage.
A1
Grey / nitric
A5
Chrome / nitric
B5
Grey / white
B6
Grey / transparent
B7
Nitric / transparent
C1
Black / nitric
D6
Dark grey / aluminium
D7
Cyan
D8
White / transparent
D9
White / nitric
E1
Grey / black / aluminium
E4
White / chrome
E5
White / grey
E6
Chrome burnished
E7
White/chrome burnished
E8
Satin gold
E9
White/ satin gold
F1
Black/ burnished chrome
F5
Rust brown
G16
Anthracite grey
00
Indeterminate
01
White
02
Orange
04
Black
05
Red
06
Yellow
07
Green
09
Sky blue
10
Chrome
12
Aluminium
13
Steel
14
Gold
15
Grey
16
Blue
21
Clear and satin
24
Clear transparent
26
Magenta
38
Opal
39
White / aluminium
40
Black / aluminium
41
White / gold
43
Black / black
44
Black / gold
47
White / black
65
Nitric
73
Grey / yellow
74
Grey / black
78
Grey / aluminium
86
Dark metallic grey
...m