Degree of protection
Classification of fittings
The resistance offered by the fixture
to the penetration of solids and
liquids is indicated by the IP prefix
(International Protection) followed
by two numbers. The first number
identifies the degree of protection
against the ingress of solids and
the second number against liquids
(IEC 529 - EN 60529 publication).
The letters IK indicate the level of
shock resistance of the luminaire,
according to CEI EN 50102.
FIRST IDENTIFICATION NUMBER
Degree of protection against
penetration of solids.
0
Not protected
1
Protected against
penetration of solids
larger than 50 mm.
2
Protected against
penetration of solids
larger than 12 mm.
3
Protected against
penetration of solids
larger than 2.5 mm.
4
Protected against the
penetration of solids
larger than 1 mm.
5
Protected against the
penetration of dust
6
Completely protected
against penetration of
dust
SECOND IDENTIFICATION NUMBER
Degree of protection against
penetration of liquids.
0
Not protected
1
Protected against the
vertical fall of water
drops
2
Protected against the fall
of water at a maximum
angle of 15°
3
Protected against rain
4
Protected against
splashes
5
Protected against
jets of water
6
Protected against
waves
7
Protected against the
effects of immersion
8
Protected against the
effects of prolonged
immersion
LEVEL OF SHOCK RESISTANCE
It designates the level of shock re-
sistance according to CEI EN 50102.
IK00
Not protected
IK01
Protected against 0.15
J shocks
IK02
Protected against 0.2 J
shocks
IK03
Protected against 0.35
J shocks
IK04
Protected against 0.5 J
shocks
IK05
Protected against 0.7 J
shocks
IK06
Protected against 1 J
shocks
IK07
Protected against 2 J
shocks
IK08
Protected against 5 J
shocks
IK09
Protected against 10 J
shocks
IK10
Protected against 20 J
shocks
Classification of fittings
according to electrical
protection.
Class I
With functional insulation
in every part and with
earth terminal or clamp
if the unit is fixed, or with
electric power supply
cable complete with
earth wires and relative
plug with earth contact if
the unit is mobile.
Class II
With double insulation
and/or reinforced
insulation in every
part and without earth
connections.
Class III
Designed for connecting
to low voltage circuits,
without any internal
or external circuit
functioning at a voltage
different from safety low
voltage.
Classification of fittings
according to the flammability of
the surfaces used for installation.
The fitting can be
installed on normally
flammable surfaces.
Class III products:
performances are assured
only when using the
electronic power supply
units and drivers indicated
in the catalogue.