510
Smoke alarm device Smoke Alarm Device Q / Accessories
Specifications
Order No.
P. unit
PS
Specifications
Order No.
P. unit
PS
Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
Smoke alarm device
Security
2337022337 02
1
03
C Optional accessories
Relay module for smoke alarm device Dual
D
510
KNX module for smoke alarm device Dual
D
511
Wireless module for smoke alarm device Dual Q
D
511
Set of spacer sleeves and screws
D
512
Features
- Dual Q smoke alarm device with mains power (230 V) for private
home use. This item does not need a mounting plate.
- The base with integrated power supply unit is used to provide the
Dual Q smoke alarm device with mains voltage (230 V).
- Connection of the supply cable or networking cable is in the
base. Contact is automatic when the smoke alarm device is
mounted.
- The battery in the Dual Q smoke alarm device automatically takes
over the power supply in the event of a mains failure.
- Up to 40 smoke alarm devices can be networked via a separate
conductor.
Technical data
Power supply:
AC 230 V, 50 Hz via base
Battery
- :
back-up only
- Type:
U9VL-J-P
- UN no.:
3091
Battery life:
at least 10 years
Acoustic signal
- Alarm:
at least 85 dB (A)
- Function test:
approx. 75 dB (A)
Visual signal
- Base:
Green LED (230 V)
- Ring indicator:
Red LED indicates status and
malfunctions
Weight:
approx. 350 g
Dimensions in mm
- Housing:
Ø 125
H 77
2340002340 00
1
03
C Necessary accessories
SAD 2346 02
D
509
Features
- Relay module for the smoke alarm device Dual Q.
- Downwards-compatible, therefore it can also be used for smoke
alarm device Dual/VdS.
- Option of connecting external alarm devices, such as a horn or
warning light.
- The alarm relay switches for local or networked alarm.
- The fault relay switches in case of a smoke alarm device fault,
e.g. weak battery.
- Using the relay module, alarm and fault messages can be
switched to another signal transmitter.
Technical data
Alarm output contact:
2-way momentary contact,
zero-voltage
Fault output contact:
2-way momentary contact,
zero-voltage
Switching voltage:
max. 30 V
Switching current:
max. 1 A
Notes
- Fault messages can only be polled by smoke alarm devices
equipped with a relay module.
- The relay module is simply plugged in at the interface of the
smoke alarm device Dual. The networking terminals of the smoke
alarm device can continue to be used when the module is
attached.
- Please note the planning information in the "Technical
Information" brochure, download.gira.de.
Dual Q smoke alarm device incl. base 230 V
Accessories
Relay module for smoke alarm device Dual