509
The Gira Dual Q smoke alarm
device is supplied with power
from a 9-V PP3 battery. The
automatic function test regularly
tests the power supply and
functions of the smoke alarm
device. If the battery voltage
drops below a defined point,
the smoke alarm device signals
for 30 days that the device has
to be replaced. The smoke alarm
device remains completely
functional during this period.
The integrated twilight sensor
switches off the battery
warning signal in darkness.
Use as individual device
Networking of up to 40 devices via the 2-wire line
230 V operation
The Gira Dual Q smoke alarm
device can also be operated via
the existing 230 V line network.
A 230 V base is available for
retrofitting the networking
capability and supplying power.
Up to 40 devices can be
networked via a separate
conductor.
Networking of up to 40 devices via a separate conductor
Networking options with the
wireless module
If a smoke alarm device with the
wireless module is programmed
as a repeater, the range can
be expanded even further. A
transmission range of 100 m
(free field) can be achieved
per wireless module.
In addition, it is possible
to integrate the Gira Dual Q
smoke alarm device with
wireless module into pre-existing
installations equipped with
Gira Dual/VdS smoke alarm
devices with wireless modules.
Networking of up to 40 devices via wireless bus system
+
+
Networking options with the
KNX module for Dual Q smoke
alarm device
The optional KNX module
enables the Gira Dual Q smoke
alarm device to be connected
to the KNX system. If the device
registers fire or smoke
accumulation, the module
forwards the signals to the KNX
system, which reacts intelligently
to the risk of fire. The KNX module
is supplied with electricity via
the KNX line. As many devices
as desired can be connected.
Networking in any desired quantity via the Gira KNX system
+
+
+
KNX line
Networking options with the
relay module
Equipped with an optional relay
module, the Gira Dual Q smoke
alarm device can be connected
to external alarm devices, such
as a sounder or beacon.
In addition, alarm and fault
messages, e. g. on a TeleCoppler
or alarm control unit, can be
switched or forwarded to the
KNX system via a button
interface.
Integration of additional devices such as a button interface, Telecoppler, or
sounder via the relay module
+
Gira Dual Q smoke alarm
device
230 V base for Dual Q smoke
alarm device
Dual Q smoke alarm device, 230
V version
Gira Dual Q smoke alarm device: options, product range
Gira Dual Q smoke alarm device: networking options
Smoke Alarm Device Q Smoke alarm device
Specifications
Order No.
P. unit
PS
Specifications
Order No.
P. unit
PS
Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
Smoke alarm device
Security
Increased quality criteria and technical advancements in smoke
alarm devices are indicated on the market with the new Q test
mark. The new Q-Label is an autonomous, manufacturer-
independent quality mark for high-quality smoke alarm devices
which undergo special testing for long-term use. The latest
generation of Gira smoke alarm devices fulfil the criteria of the new
Q-Label quality mark. The smoke alarm devices operate based on
the photoelectric scattered light principle without radioactive
particles. The smoke alarm devices detect smoke accumulation
early and emit a warning signal before the concentration of smoke
can become hazardous to people. Alerting occurs via a loud
pulsing alarm tone and a flashing LED.
Features
- Use in private residential units or similarly inhabited areas only in
accordance with DIN 14676.
Q-Label
- Tested durability and reduction of deceptive alarms.
- Increased stability, e.g. against external factors.
- Permanently installed battery with a service life of up to 10 years.
- Design A as per DIN EN 14604.
- KRIWAN approval.
Technical data
Power supply:
Via smoke alarm device battery
Battery life:
up to 10 years (after activation)
Acoustic signal:
Alarm: at least 85 dB (A)
Visual signal:
Ring indicator (red LED)
Ambient temperature:
-5 °C to +55 °C
Installation height:
max. 6 m
Protection type:
IP42
Area of application:
DIN 14676
Standards
- :
DIN 14604
- Design:
D
pure white glossy
1149021149 02
1
03
Features
- Integrated function button for function test.
- Fault indication.
- Weak battery indication.
Technical data
Batteries
- Type:
3 x CR123A
- UN no.:
3091
Dimensions in mm
- Housing:
Ø 125
H 38,5
pure white glossy
2346022346 02
1
03
C Optional accessories
relay mod. SAD Dual 2340 00
D
510
KNX module SAD Dual 2343 00
D
511
WL mod. SAD Dual Q 2347 00
D
511
set spacer sleeves screws 2342 00
D
512
Features
- Battery-operated combined smoke alarm device and heat
detector.
- Fire and heat alarms alerted differently.
- Heat detection via maximum and differential function.
- Muffled alarm signal (approx. 75 dB (A)) during function test.
- Integrated function button for alarm acknowledgement, function
test and muting, for example.
- Smoke detection deactivatable.
- Automatic smoke evaluation self-test with tracking of soiling.
- Soiling or fault indication.
- Signalling of technical faults can be delayed up to 12 h in
darkness.
- "Weak battery" indication.
- Up to 40 smoke alarm devices can be networked on each wire.
- One module interface for three optional modules (KNX module,
radio module, relay module) with simultaneous use of the
networking terminal.
Technical data
Battery
- Type:
U9VL-J-P
- UN no.:
3091
Dimensions in mm
- Housing:
Ø 125
H 48
Smoke Alarm Device Q
Smoke alarm device Basic Q
Smoke alarm device Dual Q