475
System and function overview
Transmission functions
Wireless wall transmitter
System 55
1-gang 5331 .. | D480
3-gang 5333 .. | D480
Wireless hand-held
transmitter
1-gang 5350 10 | D478
2-gang 5352 10 | D479
4-gang 5354 10 | D479
tado° heating control
Steinel sensIQ eNet
Steinel XLED PRO eNet
Wireless operating top unit
5492 xx | D 485
5493 xx | D 485
5494 xx | D 485
5495 xx | D 485
Wireless solar sensor Solar
5461 02 | D486
Wireless universal transmitter
2-gang Mini
5453 00 | D481
DRA server
5301 00 | D477
Transmission acknowledgement
Yes
Yes
No
Yes
Yes
Yes
Reception
functions
Status
display
Yes
Yes
Target temperature,
tado° mode
No
Yes
Yes
Yes
Wireless operating top unit5)
Wireless operating top unit
(arrow symbols)5)
5492 .. | D 485
5493 .. | D 485
5494 .. | D 485
5495 .. | D 485
switching
dimming
raising/lowering
positioning
scenes
switching
dimming
raising/lowering
positioning
scenes
triggering switching
commands and scenes
raising/lowering
positioning
scenes
positioning
switching
dimming
raising/lowering
positioning
scenes
programming, visualisation and
operation parameter setting
logic and timer functions,
repeater function
DRA server 1) 5)
5301 00 | D 477
programming
visualisation
parameter setting
programming
visualisation
parameter setting
Connection of the
tado° system
with eNet via
eNet server Version 2.1
programming
visualisation
parameter setting
repeater function
programming
visualisation
parameter setting
repeater function
programming
programming
visualisation
parameter setting
tado° heating control
Setting target temperature,
setting tado° mode
Setting target temperature,
setting tado° mode
Setting target temperature,
setting tado° mode
Connection of the
tado° system with eNet via
eNet server Version 2.1
Steinel sensIQ eNet5)
switching, scenes
switching, scenes
switching, scenes
switching
scenes
switching, scenes
programming, visualisation and
operation parameter setting
logic and timer functions
Steinel XLED PRO eNet5)
switching, scenes
switching, scenes
switching, scenes
switching
scenes
switching, scenes
programming, visualisation and
operation parameter setting
logic and timer functions
1) Required for power supply: 12 V DC / 2 A DRA power supply (5319 00) that supplies an eNet server or an eNet DRA wireless receiver module and up to 32 other
DRA components.
2) Requires an eNet DRA server (5301 00) or an eNet DRA wireless receiver module (5452 00) to receive wireless telegrams. An eNet server or eNet DRA wireless
receiver module can supply wireless signals to up to 32 DRA components.
3) The following wireless bus products are not supported: wireless controller (0358 18), wireless presence detector (0318 ..), wireless room temperature sensor (1186 ..),
wireless security light 180/16 (0826 02), wireless automatic control switch (1306 ..), wireless window contact (2256 ..).
4) Only possible in eNet system, not through to the wireless bus system.
5) Telegram repetition with wireless diagnostic device or eNet server can be activated.
eNet
Gira electrical installation systems
eNet
System and function overview
Transmission functions
Wireless wall transmitter
System 55
1-gang 5331 .. | D480
3-gang 5333 .. | D480
Wireless hand-held
transmitter
1-gang 5350 10 | D478
2-gang 5352 10 | D479
4-gang 5354 10 | D479
tado° heating control
Steinel sensIQ eNet
Steinel XLED PRO eNet
Wireless operating top unit
5492 xx | D 485
5493 xx | D 485
5494 xx | D 485
5495 xx | D 485
Wireless solar sensor Solar
5461 02 | D486
Wireless universal transmitter
2-gang Mini
5453 00 | D481
DRA server
5301 00 | D477
Transmission acknowledgement
Yes
Yes
No
Yes
Yes
Yes
Reception
functions
Status
display
Yes
Yes
Target temperature,
tado° mode
No
Yes
Yes
Yes
Wireless operating top unit5)
Wireless operating top unit
(arrow symbols)5)
5492 .. | D 485
5493 .. | D 485
5494 .. | D 485
5495 .. | D 485
switching
dimming
raising/lowering
positioning
scenes
switching
dimming
raising/lowering
positioning
scenes
triggering switching
commands and scenes
raising/lowering
positioning
scenes
positioning
switching
dimming
raising/lowering
positioning
scenes
programming, visualisation and
operation parameter setting
logic and timer functions,
repeater function
DRA server 1) 5)
5301 00 | D 477
programming
visualisation
parameter setting
programming
visualisation
parameter setting
Connection of the
tado° system
with eNet via
eNet server Version 2.1
programming
visualisation
parameter setting
repeater function
programming
visualisation
parameter setting
repeater function
programming
programming
visualisation
parameter setting
tado° heating control
Setting target temperature,
setting tado° mode
Setting target temperature,
setting tado° mode
Setting target temperature,
setting tado° mode
Connection of the
tado° system with eNet via
eNet server Version 2.1
Steinel sensIQ eNet5)
switching, scenes
switching, scenes
switching, scenes
switching
scenes
switching, scenes
programming, visualisation and
operation parameter setting
logic and timer functions
Steinel XLED PRO eNet5)
switching, scenes
switching, scenes
switching, scenes
switching
scenes
switching, scenes
programming, visualisation and
operation parameter setting
logic and timer functions