456
KNX Heating, ventilation, air conditioning
Specifications
Order No.
P. unit
PS
Specifications
Order No.
P. unit
PS
Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
KNX system
devices, actuators,
sensors
DRA plus
2114002114 00
1
26
C Optional accessories
therm.servo 230 V 2169 00
D
266
therm.servo 24 V 2179 00
D
267
Features
- Heating actuator for switching thermal servos for heating or
cooling ceilings.
- Control using 1-bit or 1-byte corrected variable telegrams.
- For 1-byte correcting variables, the outputs are controlled by
pulse width modulation (PWM).
- Servos with the characteristic "de-energised open" or "de-
energised closed" can be controlled.
- Servos can be activated with rated voltage 24 V or 230 V.
- Overload protected, short-circuit protected.
- Standard protection.
- Feedback via bus e.g. for overload and short circuit.
- Switching the heating circuit pump (standard functions).
- Passive group feedback of the closed servos.
Technical data
KNX medium:
TP256
Outputs:
6
Contact type:
Triac
Power loss:
max. 1 W
Switching voltage:
AC 24/230 V, 50/60 Hz
Switching current:
5 to 160 mA
Switch-on current:
max. 1.5 A (2 s)
Number of drives per output
- AC 230 V drives:
4
- AC 24 V drives:
2
Connections:
max. 4 mm²
Dimensions
- Modular widths (MW):
4
Notes
- Valves with the same operating voltage must be connected at all
outputs.
- VDE approval in accordance with EN 60669-1, EN 60669-2-1.
- Installation on DIN top-hat rail.
DRA plus
2163002163 00
1
26
Features
- Fan coil actuator for operation of ventilator convectors (fan coil
units), implemented for room air conditioning.
- The actuator receives telegrams, for example from room
temperature controllers, and converts corrected variable
telegrams into equivalent fan speeds and valve positions.
- Connection of a ventilator convector with up to six ventilator
gradations or connection of two ventilator convectors each with
up to three fan speeds with double pipe systems.
- Manual actuation.
- Building site operation: Outputs can be operated manually
without bus voltage with operating voltage only.
- Operating modes for heating or cooling mode, or combined
heating/cooling mode.
- Double tube or quadruple tube operation. Double tube system
heats or cools via a shared water cycle. Quadruple tube system
consists of separate flow and return for heating and cooling.
- Individual or hierarchic switching of fan speeds.
- Feedback, output indication, block function for each channel,
level limitation.
- Behaviour after bus voltage failure or bus/mains voltage failure
and following an ETS programming process can be configured.
- Limit values can be set.
- Cyclical or event-oriented transmission.
- Free channels can be used for switching functions, e.g. for room
lighting
Technical data
KNX medium:
TP256
Switching contact:
µ contact, 1 x zero-voltage NO
contact
Switching capacity AC 230 V:
10 A / AC1 or 10 A / AC3
Maximum switch-on current
- 200 µs:
800 A
- 20 ms:
165 A
Connected load
- Ohmic load:
2300 W
- Capacitive load AC 230 V:
10 A, max. 140 µF
- Light bulbs:
2300 W
- HV halogen lamps:
2300 W
- Wound transformer:
1200 VA
- Tronic transformer:
1500 W
- Fluorescent lamps,
uncompensated:
1000 VA
- Fluorescent lamps, duo-
circuit:
2300 VA
- Fluorescent lamps, parallel-
compensated:
1160 VA
- Mercury-vapour lamps,
uncompensated:
1000 W
- Mercury-vapour lamps,
parallel-compensated:
1160 W
Connections
- KNX:
Connection and junction terminal
- Load:
Screw terminals
- Connections:
max. 4 mm²
Dimensions
- Modular widths (MW):
4
Notes
- VDE approval in accordance with EN 60669-1, EN 60669-2-1.
- Installation on DIN top-hat rail.
Scope of supply
- KNX connection and junction terminal included in the scope of
supply.
KNX heating actuator Basic, 6-gang
KNX fan coil actuator