Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
KNX system
devices, actuators,
sensors
DRA plus
2161002161 00
1
66
Features
- For mains voltage AC 230 V (8 channel) or low voltage DC 12 to
48 V (4 channel).
- Connection of various external conductors.
- Independent control of the blind outputs.
- Automatic curtain moving time detection for AC 230 V drives
with mechanical stop position switches.
Technical data
Rated voltage:
AC 230 V, 50/60 Hz
AC switching voltage:
AC 230 V, 50/60 Hz
Switching capacity AC 230 V:
6 A / AC1
Switching voltage DC:
DC 12 to 48 V
Switching capacity
- DC 12/24 V:
6 A
- DC 48 V:
3 A
Connections:
max. 4 mm²
Dimensions
- Modular widths (MW):
8
Notes
- VDE approval in accordance with EN 60669-1, EN 60669-2-1.
Scope of supply
- KNX connection and junction terminal included in the scope of
supply.
DRA plus
2160002160 00
1
26
Features
- Shutter actuator with manual actuation and status display for
each output.
- With integrated bus coupler.
- For controlling electrically operated shutters for mains voltage of
AC 230 V (4-channel).
- Connection of various external conductors.
- Independent control of the four shutter outputs.
- Shutter position can be directly controlled.
- Behaviour after bus voltage failure and recovery can be set.
- Feedback of position. Active or passive (object can be read out)
cyclical feedback functions.
- Assignments of up to five different safety functions (three wind
alarms, one rain alarm, one frost alarm) or optionally with cyclical
monitoring.
- Building site operation: Outputs can be operated manually
without bus voltage with operating voltage only.
Technical data
KNX medium:
TP256
Rated voltage:
AC 230 V, 50/60 Hz
AC switching voltage:
AC 230 V, 50/60 Hz
Switching capacity AC 230 V:
6 A / AC1
Connections
- KNX:
Connection and junction terminal
- Load:
load via screw terminals
- Connections:
max. 4 mm²
Dimensions
- Modular widths (MW):
4
Notes
- VDE approval in accordance with EN 60669-1, EN 60669-2-1.
- Installation on DIN top-hat rail.
Scope of supply
- KNX connection and junction terminal included in the scope of
supply.
KNX blind actuator, 8-gang AC 230 V / DC 12 - 48 V
with manual actuation
Shutter
KNX shutter actuator, 4-gang AC 230 V with