433
Flush-mounted actuators KNX
Specifications
Order No.
P. unit
PS
Specifications
Order No.
P. unit
PS
Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
KNX system
devices, actuators,
sensors
Flush-mounted
5062005062 00
1/5
06
C Optional accessories
remote sens. 1493 00
D
370
leakage sensor 5068 00
D
461
condensation sens. 5069 00
D
461
junction box 0070 30
D
134
install.adapter mini hous. 5429 00
D
434
Features
- Blind or switching operation can be parametrised. In blind
operation, both outputs (A1/A2) are combined into one blind
output.
- Device has three inputs with a common reference potential.
- Read-in of switching states of installation switches or buttons
and other zero-voltage contacts at inputs 1 to 3.
- Signal analysis of dew and leakage sensors (see accessories) at
inputs 1 to 3.
- Recording of temperature values via remote sensors (see
accessories) at input 3.
- Up to 8 independent logic functions for implementing simple or
complex logical operations.
- Actively transmitting feedback or status messages can be
delayed after a bus voltage recovery or ETS programming mode.
- Bistable relay.
Blind functions
- Operating mode can be parametrised: Control of slat blinds, roller
shutters, awnings, skylights or ventilation flaps.
- Separately parameterisable movement times with movement time
extension for movements into the upper end position.
- For slat blinds, a slat movement time can be parametrised
independently.
- Switchover time for change of direction and times for short and
long-term operation (Step, Move) can be set.
- Reaction in case of bus voltage recovery can be set following an
ETS programming process.
- Central control via up to 6 long-term objects possible (UP,
DOWN, permanently UP, permanently DOWN).
- Feedback on the curtain or slat position. In addition, feedback on
an invalid curtain position or a drive movement is possible. Active
(send to the bus in case of change or cyclically) or passive (object
can be read out) feedback functions.
- Assignments of up to five different safety functions (3 wind
alarms, 1 rain alarm, 1 frost alarm), with cyclical monitoring as an
option.
- Comprehensive sun protection function with fixed and variable
curtain or slat positions at the beginning or end of the function
can be activated. Including dynamic slat offset for slat blinds.
Also with extended sun protection for integration in more
complex shading control systems (has separate automatic and
blocking objects). Optionally also with automatic heating/cooling
and presence function.
- Fabric tensioning function for awnings.
- Extended blocking function with acknowledgement option.
- Ventilation function for windows with window contacts.
- Intelligent teaching function for curtain movement.
- Forced setting function or blocking function can be implemented.
- Up to 64 internal scenes can be parametrised.
- Scene memory function: Additional visual feedback.
- Extended scene retrieval (toggling of scenes).
Switching functions
- Independent switching of the switching outputs.
- NO contact or NC contact operation.
- Central switching function via up to 6 switch objects (ON, OFF,
permanently ON, permanently OFF).
- Feedback on switching: Active or passive feedback function.
- Reaction in case of bus voltage failure or bus voltage recovery
can be set following an ETS programming process.
- Logical individual linking function for each output.
- Blocking function can be parametrised for each channel.
Alternative separate forced setting function for each output.
- Extended blocking function with acknowledgement option.
- Time functions (switch-on and switch-off delay, staircase light
function – also with advance warning function).
- Can be integrated into light scenes: Up to 64 internal scenes can
be parametrised per output.
- Scene memory function: Additional visual feedback.
- Extended scene retrieval (toggling of scenes).
- Elapsed operating time meter can be activated individually for
each output.
- Input monitoring for cyclic updating of the switching object with
safety position.
Technical data
Rated voltage
- KNX:
DC 21 to 32 V SELV
Switching capacity:
AC 250 V, Σ 16 AX
Maximum switch-on current:
800 A (200 µs), 165 A (20 ms)
Connected load
- Ohmic load:
2500 W
- Capacitive load:
16 A, max. 140 µF
- Motors (blind or fan):
1380 W
- Light bulbs:
2300 W
- HV halogen lamps:
2300 W
- HV LED lamps:
typically 400 W
- Wound transformer:
1200 VA
- Tronic transformer:
1500 W
- Fluorescent lamps,
uncompensated:
1000 VA
- Fluorescent lamps, duo-
circuit:
2300 VA
- Fluorescent lamps, parallel-
compensated:
1160 VA
Notes
- Power reduction
Reduction of switching current per device (based on Σ 16 A) per
5 °C in excess of 35 °C -10%
For installation in
Wood or drywall -15%
Multiple combinations -20%.
N New product.
Replaces 1057 00
KNX switching actuator, 2-gang / blind actuator,
1-gang 16 A with binary input, 3-gang