379
System and function overview
Room temperature controller inserts
Order no.
KNX RF operating top unit, 1-gang
KNX RF operating top unit, 2-gang
5104 .. | D 380
5107 .. | D 380
5105 .. | D 380
5108 .. | D 381
5106 .. | D 380
Performance features of the combinations of KNX
RF operating top units and System 3000 room
temperature controller inserts
– Local control of System 3000 insert possible
– Control of other KNX devices via KNX RF possible
Function overview of KNX RF operating top units
and System 3000 inserts
Functions of the operating top unit
– Switching
– Dimming and colour control
– Blinds
– Scene auxiliary unit
– Controller auxiliary unit
– 2-channel operation
– Value transmitter
Functions of the insert
– Control of 230 V servos
– Heating mode, cooling mode, heating and cooling
mode
– PWM and 2-point controller
– Absolute and relative setpoint setting
– Heating requirements control incl. cascading
– Valve protection function
System 3000 room
temperature con-
troller insert with
sensor connection
5395 00 | D 197
Connection of auxiliary units possible
Yes, switching between heating and cooling mode
Connection of a remote sensor possible
Yes
Temperature detection possible
Yes
System 3000 relay
switching insert
5403 00 | D 182
Connection of auxiliary units possible
Yes:
1. Local control of the insert
2. Control of other KNX devices
3. Switching between heating and cooling mode
Connection of a remote sensor possible
No
Temperature detection possible
Yes
System 3000 elec-
tronic switching
insert
5405 00 | D 185
Connection of auxiliary units possible
Yes:
1. Local control of the insert
2. Control of other KNX devices
3. Switching between heating and cooling mode
Connection of a remote sensor possible
No
Temperature detection possible
Yes
Blind inserts
Order no.
KNX RF operating top unit, 1-gang
KNX RF operating top unit, 2-gang
5104 .. | D 380
5107 .. | D 380
5105 .. | D 380
5108 .. | D 381
5106 .. | D 380
Performance features of the combinations of KNX
RF operating top units and System 3000 blind
inserts
– Local control of System 3000 insert possible
– Control of other KNX devices via KNX RF possible
Function overview of KNX RF operating top units
and System 3000 inserts
Functions of the operating top unit
– Switching
– Dimming and colour control
– Blinds
– Scene auxiliary unit
– Controller auxiliary unit
– 2-channel operation
– Value transmitter
Functions of the insert
– Type of curtain selectable
– Safety function (wind, rain, frost alarm)
– Sun protection function
– Scene function
– Blocking function
System 3000 blind
controller insert
with auxiliary input
5414 00 | D 196
Connection of auxiliary units possible
Yes, local control of the insert
Temperature detection possible
Yes
System 3000 blind
controller insert
without auxiliary
input
5415 00 | D 196
Connection of auxiliary units possible
No
Temperature detection possible
Yes
Operating top units KNX RF
Specifications
Order No.
P. unit
PS
Specifications
Order No.
P. unit
PS
Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
KNX RF
Features
- KNX RF operating top unit for controlling System 3000 inserts as
well as remote KNX devices using KNX RF.
- Rocker or button function can be set for each operating surface.
- Control of up to four functions possible using the button function
of the KNX RF operating top unit.
- KNX RF actuator in combination with System 3000 inserts.
- Operation on switching, dimming, blind or room temperature
controller insert, as well as the System 3000 three-wire auxiliary
insert.
- Integrated temperature sensor.
- Integrated repeater mode.
Room temperature measurement
- The RF operating top unit has an internal temperature sensor,
which makes it possible to measure and forward the local room
temperature.
- Temperature measurements are only possible in combination
with the following inserts: Order no. 5403 00, order no. 5405 00,
order no. 5406 00, order no. 5414 00, order no. 5415 00, order no.
5395 00, order no. 5409 00.
Operating functions depend on which flush-mounted insert is
used
- The RF operating top unit can be operated with the System 3000
three-wire auxiliary unit as a KNX RF operating device powered
by 230 V.
- The button or rocker function operating concept can be
parametrised.
- Switching, dimming and colour temperature, colour control and
brightness, blinds, value transmitter, scene auxiliary unit,
two-channel operation and controller auxiliary unit.
- Switching: The command when pressing and / or releasing is
adjustable (No reaction, Switch on, Switch off, Switch over).
- Dimming and colour temperature: Brightness and/or colour
temperature, the command when pressing, the time between
switching and dimming, the dimming in different steps, the
telegram repetition if pressed for a long time and the sending of a
stop telegram at the end of pressing can be set.
- Colour control and brightness: Colour cycle or brightness
adjustment, the command when pressing, the time between
switching and dimming, the start value, the increment and the
time between two telegrams can be set.
- Blinds: The command when pressed and the operating concept
are adjustable. The operating concept can be adapted in the
times for short and long actuation and slat adjustment.
- Value transmitter: The mode of operation (1 byte, 2 byte, 3 byte
or 6 byte value transmitter) and the value are adjustable.
- Scene auxiliary unit: The mode of operation (with or without
memory function) and the scene number are adjustable.
- 2-channel operation: Up to two telegrams can be sent to the KNX
by pressing a button. The operating concept can be set and the
time for short and long actuation can be adjusted. The mode of
operation of the channels can be set separately.
- Controller auxiliary unit: The mode of operation (operating mode
switch-over, forced operating mode switch-over, presence
function and setpoint offset) can be set.
- Function for disabling individual buttons or rockers.
Controller auxiliary unit properties
- The controller auxiliary unit can be parametrised as the function
of a rocker or button. Control of a room temperature controller
(operating modes, presence function and setpoint offset).
- Evaluation of the controller status via the status LED.
- Temperature measurement can be activated. Measurement of the
room temperature with an internal sensor or optionally by
creating a measured value of the internally measured
temperature with an external temperature.
Functions of the status LEDs
- The function selection is made for each status LED. The following
functions can be parametrised: always OFF, always ON, actuation
display, telegram acknowledgement, status display, control with
separate LED object, operating mode display, controller status
display, presence status display and setpoint offset display.
- Colour can be parametrised. The colour selection is performed
either for all status LEDs or separately for each status LED of the
device. The status LEDs can light up optionally in red, green or
blue.
- The status LEDs have six adjustable brightness levels. With night-
time reduction, the brightness of the status LEDs can be reduced
in the night hours via a communication object.
Switching actuator functions
- The RF operating top unit can be operated with System 3000
switching inserts.
- Switching actuator channel 1-gang/2-gang.
- Temperature detection possible with order no. 5403 00 and order
no. 5405 00.
- Insert function selection for switching:
NO/NC operation, staircase function, scene function (16 scenes),
blocking function, time delays.
Auxiliary input can be used as an additional operating point for
the System 3000 insert or for wireless control of other KNX
devices as a sensor.
Dimming actuator and DALI actuator functions
- The RF operating top unit can be operated with System 3000
dimming inserts.
- Temperature detection with order no. 5406 00.
- Insert function selection for dimming:
Adjustable dimming principle for dimming inserts, staircase
function, scene function (16 scenes), blocking function, time
delays.
Auxiliary input can be used as an additional operating point for
the System 3000 insert or for wireless control of other KNX
devices as a sensor.
Blind actuator functions
- The RF operating top unit can be operated with System 3000
blind inserts.
- Blind actuator channel 1-gang.
- Temperature detection possible.
- Insert function selection for blind control:
Curtain type selectable, safety function (wind, rain, frost alarm),
sun protection function, scene function (16 scenes), blocking
function.
Heating actuator functions
- The RF operating top unit can be operated with System 3000
room temperature controller inserts.
- Heating actuator channel 1-gang with order no. 5403 00, order
no. 5405 00, order no. 5395 00.
- Insert function selection for room temperature controller:
Control of 230 V servos, heating mode, cooling mode, heating
and cooling mode, PWM and two-point controller, absolute and
relative setpoint setting, heating requirement control incl.
cascading, valve protection function, scene function (16 scenes).
Auxiliary input is used to switch between heating and cooling
mode.
Alternatively, the auxiliary input can be used as an additional
operating point for the System 3000 insert or for wireless control
of other KNX devices as a sensor.
Technical data
KNX medium:
RF1.R
Wireless frequency:
868.0 to 868.6 MHz
Transmission power:
max. 20 mW
Transmission range:
approx. 100 m
Ambient temperature:
-5 °C to +45 °C
Notes
- KNX Data Secure compatible.
- Fast application download (long frame support).
- Firmware can be updated using the Gira ETS Service App
(additional software).
KNX RF operating top units