378
KNX RF
Gira electrical installation systems
KNX RF
System and function overview
Room temperature controller inserts
Order no.
KNX RF operating top unit, 1-gang
KNX RF operating top unit, 2-gang
5104 .. | D 380
5107 .. | D 380
5105 .. | D 380
5108 .. | D 381
5106 .. | D 380
Performance features of the combinations of KNX
RF operating top units and System 3000 room
temperature controller inserts
– Local control of System 3000 insert possible
– Control of other KNX devices via KNX RF possible
Function overview of KNX RF operating top units
and System 3000 inserts
Functions of the operating top unit
– Switching
– Dimming and colour control
– Blinds
– Scene auxiliary unit
– Controller auxiliary unit
– 2-channel operation
– Value transmitter
Functions of the insert
– Control of 230 V servos
– Heating mode, cooling mode, heating and cooling
mode
– PWM and 2-point controller
– Absolute and relative setpoint setting
– Heating requirements control incl. cascading
– Valve protection function
System 3000 room
temperature con-
troller insert with
sensor connection
5395 00 | D 197
Connection of auxiliary units possible
Yes, switching between heating and cooling mode
Connection of a remote sensor possible
Yes
Temperature detection possible
Yes
System 3000 relay
switching insert
5403 00 | D 182
Connection of auxiliary units possible
Yes:
1. Local control of the insert
2. Control of other KNX devices
3. Switching between heating and cooling mode
Connection of a remote sensor possible
No
Temperature detection possible
Yes
System 3000 elec-
tronic switching
insert
5405 00 | D 185
Connection of auxiliary units possible
Yes:
1. Local control of the insert
2. Control of other KNX devices
3. Switching between heating and cooling mode
Connection of a remote sensor possible
No
Temperature detection possible
Yes
Blind inserts
Order no.
KNX RF operating top unit, 1-gang
KNX RF operating top unit, 2-gang
5104 .. | D 380
5107 .. | D 380
5105 .. | D 380
5108 .. | D 381
5106 .. | D 380
Performance features of the combinations of KNX
RF operating top units and System 3000 blind
inserts
– Local control of System 3000 insert possible
– Control of other KNX devices via KNX RF possible
Function overview of KNX RF operating top units
and System 3000 inserts
Functions of the operating top unit
– Switching
– Dimming and colour control
– Blinds
– Scene auxiliary unit
– Controller auxiliary unit
– 2-channel operation
– Value transmitter
Functions of the insert
– Type of curtain selectable
– Safety function (wind, rain, frost alarm)
– Sun protection function
– Scene function
– Blocking function
System 3000 blind
controller insert
with auxiliary input
5414 00 | D 196
Connection of auxiliary units possible
Yes, local control of the insert
Temperature detection possible
Yes
System 3000 blind
controller insert
without auxiliary
input
5415 00 | D 196
Connection of auxiliary units possible
No
Temperature detection possible
Yes