350
KNX operating devices KNX bus coupler
Specifications
Order No.
P. unit
PS
Specifications
Order No.
P. unit
PS
Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
KNX operating
devices
2008002008 00
1/5
46
C Necessary accessories
One of the following articles:
Pushbutton sensor 3 System 55
KNX PB sens.3 Basis 1-g 5111 00
D
351
KNX PB sens.3 Basis 2-g (1+1) 5112 00
D
351
KNX PB sens.3 Basis 3-g 5113 00
D
351
KNX PB sens.3 Komfort 1-g 5131 00
D
352
KNX PB sens.3 Komfort 2-g (1+1) 5132 00
D
352
KNX PB sens.3 Komfort 3-g 5133 00
D
352
KNX PB sens.3 Komfort 4-g (1+3) 5134 00
D
353
KNX PB sens.3 Komfort 6-g (3+3) 5136 00
D
353
KNX motion detector top unit
KNX mot.det.top 1.10 m Standard 2040 ..
D
422
KNX mot.det.top 1.10 m Komfort 2050 ..
D
423
KNX mot.det.top 2.20 m Standard 2041 ..
D
424
KNX mot.det.top 2.20 m Komfort 2051 ..
D
425
C Optional accessories
prot.cov.pl. bus coup. 0015 01
D
371
Pushbutton sensor 3 Plus System 55 in operation without
external sensor
KNX PB sens.3 Plus 2-g 5142 00
D
354
KNX PB sens.3 Plus 5-g (2+3) 5145 00
D
354
Features
- The bus coupler 3 connects the KNX system to a KNX application
module.
- The combination of bus coupler 3 and application module
represents a functional unit.
- In the ETS project, this unit is configured in the form of the
application program of the application module.
Technical data
KNX medium:
TP256
KNX connection:
Connection and junction terminal
Protection class:
III
Installation depth:
22 mm
Ambient temperature:
-25 °C to +55 °C
Scope of supply
- KNX connection and junction terminal included in the scope of
supply.
2009002009 00
1/5
06
C Necessary accessories
One of the following articles:
Pushbutton sensor 3 Plus System 55
KNX PB sens.3 Plus 2-g 5142 00
D
354
KNX PB sens.3 Plus 5-g (2+3) 5145 00
D
354
C Optional accessories
remote sens. 1493 00
D
370
prot.cov.pl. bus coup. 0015 01
D
371
Features
- The bus coupler 3 connects the KNX system to a KNX application
module.
- The combination of bus coupler 3 and application module
represents a functional unit.
- In the ETS project, this unit is configured in the form of the
application program of the application module.
- In addition, a remote temperature sensor can be connected to the
bus coupler 3 with remote sensor. This enables a room
temperature controller to record the temperature at an additional
measuring point.
Technical data
KNX medium:
TP256
KNX connection:
Connection and junction terminal
Protection class:
III
Installation depth:
25 mm
Ambient temperature:
-25 °C to +55 °C
Notes
- The remote sensor functions only in combination with the
pushbutton sensor 3 Plus.
Scope of supply
- KNX connection and junction terminal included in the scope of
supply.
KNX bus coupler
Insert for KNX bus coupler 3
Insert for KNX bus coupler 3 with external sensor