309
Control Devices Door communication system devices
Specifications
Order No.
P. unit
PS
Specifications
Order No.
P. unit
PS
Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
Door
communication
system devices
DRA
1296001296 00
1
18
C Optional accessories
From the 3rd camera, necessary for
Gira door stations
D
271
Gateway
DCS-IP gateway 5 licences 2620 97
D
305
DCS-IP gateway 10 licences 2620 98
D
305
DCS-IP gateway 20 licences 2620 99
D
305
Keyless In
Gira Keyless In keypad mod. 2605 ..
D
319
Gira S1
Gira S1 2089 00
D
400
Features
- Power supply DC 24 V to supply power to the door
communication components.
- Power supply to the colour camera in large properties.
- Power supply to the call-button illumination in large properties.
- Supply of Keyless In keypad.
Technical data
Rated voltage
- Primary:
AC 230 V, 50 Hz
Secondary rated voltage
- Secondary:
DC 24 V SELV
Secondary rated current:
0.3 A
Fuse:
Micro-fuse 250 V, 160 mA
Ambient temperature:
-5 °C to +40 °C
Dimensions
- Modular widths (MW):
5
DRA
2570002570 00
1
18
Technical data
Rated voltage
- Primary:
AC 230 V, 50 Hz
Secondary rated voltage
- Secondary:
DC 24 V SELV
Secondary rated current:
0.7 A
Fuse:
Electronic self-resetting
Ambient temperature:
-5 °C to +40 °C
Dimensions
- Modular widths (MW):
6
DRA
5319005319 00
1
42
C Optional accessories
Door communication
external camera 1220 00
D
311
eNet
server DRA 5301 00
D
477
WL receiver mod. DRA 5452 00
D
478
Features
- Power supply DC 12 V for the eNet server, eNet radio reception
module and external camera.
Technical data
Rated voltage
- Primary:
AC 100 to 240 V, 50/60 Hz
- Secondary:
DC 12 to 14 V
Rated current
- Secondary:
2 A
Leakage current:
max. 250 µA
Ambient temperature:
-10 °C to +50 °C
Dimensions
- Modular widths (MW):
2
Power supply DC 24 V 300 mA
Power supply DC 24 V 700 mA
Power supply DC 12 V / 2 A