186
Gira System 3000 Switching / Dimming
Specifications
Order No.
P. unit
PS
Specifications
Order No.
P. unit
PS
Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
System 3000
Inserts, top units
DRA
0821000821 00
1
02
C Necessary accessories
S3000 impulse insert 5410 00
D
185
C Optional accessories
rocker btn NO con. 0151 00
D
165
S3000 aux.ins. 2-wire 5408 00
D
194
S3000 impulse insert 5410 00
D
185
Features
- Manual or automatic light switching in staircases.
- Switch light on using System 2000 and System 3000 impulse
insert or rocker buttons.
- Delay time adjustable.
- Electronic overload protection for the control input.
- Automatic function with or without a switch-off pre-warning.
- Switch light on or off permanently.
- Insert in 3- or 4-conductor circuit.
Technical data
Rated voltage:
AC 230 V, 50 Hz
Current load of control input A1:
40 mA
Switching voltage:
AC 250 V
Ohmic switching current:
16 A
Switch-on current 20 ms:
max. 165 A
Minimum switching current AC:
100 mA
Connected load
- HV LED lamps:
typically 400 W
- Light bulbs:
2300 W
- HV halogen lamps:
2300 W
- Tronic transformer:
1500 W
- Wound transformer:
1000 VA
- Fluorescent lamps,
uncompensated:
1200 VA
- Fluorescent lamps, duo-
circuit:
2300 (140 µF)
- Fluorescent lamps, parallel-
compensated:
920 VA
- Electronic ballasts:
type dependent
Cable length
- Load:
max. 100 m
- Control line:
max. 100 m
Switch-on time:
10 s to 15 min
Ambient temperature:
+5 °C to +45 °C
Dimensions
- Modular widths (MW):
1
2450002450 00
1/5
02
C Necessary accessories
cov. knob 0650 ..
D
38
C Optional accessories
compensation mod. LED 2375 00
D
219
Power booster
S3000 uni.LED pow.booster DRA 2383 00
D
192
Features
- Switching and dimming light bulbs, HV halogen lamps, electronic
transformers for halogen or LED lamps, dimmable inductive
transformers for halogen or LED lamps, HV LED or compact
fluorescent lamps.
- Automatic setting of dimming principle according to load (leading
or trailing edge).
- Bulb-saving switch-on.
- Switch-on brightness can be saved permanently.
- Switch on with the last brightness set, or a saved switch-on
brightness.
- Minimum brightness can be set.
- Electronic short-circuit protection.
- Electronic excess-temperature protection.
- Operation with and without neutral conductor connection.
Technical data
Rated voltage:
AC 230 V, 50/60 Hz
Standby:
max. 0.35 W
Connected load at 25 °C
- HV LED lamps (leading edge):
typ. 3 to 60 W
- HV LED lamps (trailing edge):
typically 3 to 120 W
- Compact fluorescent lamp:
typ. 3 to 60 W
- Light bulbs:
20 to 210 W
- HV halogen lamps:
20 to 210 W
- Gira tronic transformers:
20 to 210 W
- electronic transformer with
NV-LED:
typically 20 to 60 W
- Wound transformer:
20 to 210 VA
- Wound transformer with
NV-LED:
typically 20 to 60 VA
Cable length
- Load:
max. 100 m
Installation:
in device box pursuant to
DIN 49073
Installation depth:
24 mm
Connections
- Single-wire:
max. 4 mm²
- Fine-wire without ferrule:
max. 4 mm²
- Fine-wire with ferrule:
max. 4 mm²
Ambient temperature:
-5 °C to +45 °C
Notes
- In general, operating the dimmer without connecting a neutral
conductor is possible, although some LED and CFLi light sources
require the neutral conductor connection to prevent flickering.
- For operation without a neutral conductor, the minimum load for
light bulbs, HV halogen lamps, Tronic transformers, and wound
transformers increases to 50 W.
- Electronic transformers and ballast devices for LED lamps can be
operated with the dimming procedure stated by the
manufacturer.
- If the ambient temperature is higher than 25 °C, the connected
load must be reduced.
Staircase light timer
System 3000 dimming
System 3000 universal LED rotary dimming insert
Standard