185
Switching Gira System 3000
Specifications
Order No.
P. unit
PS
Specifications
Order No.
P. unit
PS
Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
System 3000
Inserts, top units
5405005405 00
1
02
C Necessary accessories
See listing at
S3000 relay swit.ins. 5403 00
D
182
C Optional accessories
rocker btn NO con. 0151 00
D
165
S3000 aux.ins. 2-wire 5408 00
D
194
S3000 aux.ins. 3-wire 5409 00
D
194
Features
- Connecting auxiliary units is possible.
- Control of thermal servos in combination with a room
temperature controller top unit.
- Bulb-saving switch-on.
- Electronic short-circuit protection.
- Electronic excess-temperature protection.
- Operation with and without neutral conductor connection.
Operation with a neutral conductor
- Switching of light bulbs, HV halogen lamps, electronic or
inductive transformers with halogen or LED lamps, switchable or
dimmable HV LED lamps or compact fluorescent lamps.
- Device is powered via the phase conductor and neutral
conductor, therefore no leading edge or trailing edge phase
control.
Operation without a neutral conductor
- Switching of light bulbs, HV halogen lamps, electronic or
inductive transformers with halogen or LED lamps, dimmable HV
LED lamps or compact fluorescent lamps.
- Device is powered via the the phase conductor and therefore
works according to the leading edge or trailing edge principle.
- Automatic or manual setting of dimming principle according to
load (leading or trailing edge).
- Display of the selected operating mode using LED.
Combination with KNX RF operating top unit, 1-gang/2-gang
- Switching actuator channel, 1-gang or heating actuator, 1-gang.
- Sensor channel, 1-gang or 2-gang.
- Local control of System 3000 insert possible.
- Wireless control of other KNX devices as sensor possible.
- Temperature detection
- Insert function selection for switching:
NO/NC operation, staircase function, scene function, blocking
function, time delays.
Auxiliary input can be used as an additional operating point for
the System 3000 insert or for wireless control of other KNX
devices as a sensor.
- Insert function selection for room temperature controller:
Control of 230 V servos, heating mode, cooling mode, heating
and cooling mode, PWM and 2-point controller, absolute and
relative setpoint setting, heating requirement control incl.
cascading, valve protection function.
Auxiliary input can be used as an additional operating point for
the System 3000 insert or for wireless control of other KNX
devices as a sensor. Alternatively, the auxiliary input can be
parameterised for switching between heating and cooling mode.
Technical data
Rated voltage:
AC 230 V, 50/60 Hz
Standby:
0.1 to 0.5 W
Connected load at 25 °C
- HV LED lamps (leading edge):
typ. 3 to 100 W
- HV LED lamps (trailing edge):
typically 3 to 200 W
- Compact fluorescent lamp:
typ. 3 to 100 W
- Light bulbs:
20 to 400 W
- HV halogen lamps:
20 to 400 W
- Gira tronic transformers:
20 to 400 W
- electronic transformer with
NV-LED:
typically 20 to 100 W
- Wound transformer:
20 to 400 VA
- Wound transformer with
NV-LED:
typically 20 to 100 VA
Thermal servos:
max. 10
Cable length
- Load:
max. 100 m
- Auxiliary unit:
max. 100 m
Installation depth:
24 mm
Installation:
in device box pursuant to DIN
49073
Ambient temperature:
-5 °C to +45 °C
Notes
- For operation without a neutral conductor, the minimum load for
light bulbs, HV halogen lamps, Tronic transformers, and wound
transformers increases to 50 W.
- If the ambient temperature is higher than 25 °C, the connected
load must be reduced.
5410005410 00
1
02
C Necessary accessories
One of the following articles:
System 3000 system top units
S3000 op.top 5360 ..
D
198
S3000 op.top arrows 5361 ..
D
198
System 3000 motion detector top units
S3000 mot.det.top 1.10 m Standard 5373 ..
D
202
S3000 mot.det.top 1.10 m Komfort BT 5374 ..
D
203
S3000 mot.det.top 2.20 m Standard 5375 ..
D
204
S3000 mot.det.top 2.20 m Komfort BT 5376 ..
D
204
S3000 pres. + mot.det. 360° top BT 5377 02
D
205
C Optional accessories
staircase light timer DRA 0821 00
D
186
Features
- The staircase lighting mechanism is switched on manually or
automatically.
- Manual switching with System 3000 operating top unit.
- Automatic switching with motion detector top unit or Bluetooth
presence and motion detector 360° top unit from the System
3000.
Technical data
Rated voltage:
AC 230 V, 50 Hz
Standby:
0.25 to 0.45 W
Current consumption:
approx. 2.8 mA
Installation depth:
24 mm
Installation:
in device box pursuant to DIN
49073
Ambient temperature:
-5 °C to +45 °C
System 3000 electronic switching insert
System 3000 impulse insert