182
Gira System 3000 Switching
Specifications
Order No.
P. unit
PS
Specifications
Order No.
P. unit
PS
Gira electrical installation systems
Price system (PS) ≠ 1, 14: reduced discount
System 3000
Inserts, top units
5403005403 00
1/5
02
C Necessary accessories
One of the following articles:
System 3000 system top units
S3000 op.top 5360 ..
D
198
S3000 op.top arrows 5361 ..
D
198
S3000 touch top 5365 ..
D
198
S3000 op.top Memory arrows 5363 ..
D
199
S3000 blind timer + timer Display 5366 ..
D
199
S3000 op.top BT 5368 ..
D
200
S3000 blind timer + timer BT 5367 ..
D
200
S3000 RTC Display 5393 ..
D
201
S3000 RTC BT 5394 ..
D
201
System 3000 motion detector top units
S3000 mot.det.top 1.10 m Standard 5373 ..
D
202
S3000 mot.det.top 1.10 m Komfort BT 5374 ..
D
203
S3000 mot.det.top 2.20 m Standard 5375 ..
D
204
S3000 mot.det.top 2.20 m Komfort BT 5376 ..
D
204
S3000 pres. + mot.det. 360° top BT 5377 02
D
205
KNX RF operating top units
KNX RF op.top 1-g 5104 ..
D
380
KNX RF op.top 1-g arrows 5105 ..
D
380
KNX RF op.top 1-g heat.mode 5106 ..
D
380
KNX RF op.top 2-g 5107 ..
D
380
KNX RF op.top 2-g arrows 5108 ..
D
381
System 3000 wireless operating top units
Gira eNet WL op.top 5495 ..
D
484
Gira eNet WL op.top arrows 5494 ..
D
484
Gira eNet WL op.top Memory 5493 ..
D
485
Gira eNet WL op.top Memory arrows 5492 ..
D
485
C Optional accessories
rocker btn NO con. 0151 00
D
165
S3000 aux.ins. 2-wire 5408 00
D
194
S3000 aux.ins. 3-wire 5409 00
D
194
Features
- Switching of lighting and single-phase motors.
- Control of electric underfloor heating and thermal servos in
combination with a room temperature controller top unit.
- Adaptive zero-point switch-off
- Connecting auxiliary units is possible.
- The load is switched off automatically. Delay times can be set to
one of five levels, cannot be re-triggered.
- Test run for function testing.
- Operation with neutral conductor connection.
Combination with KNX RF operating top unit, 1-gang/2-gang
- Switching actuator channel, 1-gang or heating actuator, 1-gang
- Sensor channel, 1-gang or 2-gang.
- Local control of System 3000 insert possible.
- Wireless control of other KNX devices as sensor possible.
- Temperature detection.
- Insert function selection for switching:
NO/NC operation, staircase function, scene function, blocking
function, time delays.
Auxiliary input can be used as an additional operating point for
the System 3000 insert or for wireless control of other KNX
devices as a sensor.
- Insert function selection for room temperature controller:
Control of 230 V servos, heating mode, cooling mode, heating
and cooling mode, PWM and 2-point controller, absolute and
relative setpoint setting, heating requirement control incl.
cascading, valve protection function.
Technical data
Rated voltage:
AC 230 V, 50/60 Hz
Standby:
0.1 to 0.5 W
Ohmic switching current:
16 A (AC1)
Connected load at 35 °C
- HV LED lamps:
typically 400 W
- Compact fluorescent lamp:
typ. 500 W
- Light bulbs:
2300 W
- HV halogen lamps:
2300 W
- Gira tronic transformers:
1500 W
- Wound transformer:
1000 VA
- Fluorescent lamps,
uncompensated:
1200 VA
Switching current for motors:
6 A
Capacitive load:
920 VA (115 µF)
Delay time:
without, 1 min, 5 min, 30 min,
60 min
Installation depth:
24 mm
Installation:
in device box pursuant to DIN
49073
Ambient temperature:
-25 °C to +45 °C
Notes
- If the ambient temperature is higher than 35 °C, the connected
load must be reduced.
System 3000 Switching