180
Gira System 3000
Gira electrical installation systems
System 3000
Inserts, top units
System 3000
Lighting control
Lighting control
Blind control
Heating control
Order no.
Relais
switching
insert,
zero-voltage
D 183
5407 00
Relais
switching
insert
D 182
5403 00
Relais
switching
insert, 2-gang
D 184
5404 00
Electronic
switching
insert
D 185
5405 00
Universal LED
dimming insert
Standard
D 188
5400 00
Universal LED
dimming insert
Komfort
D 189
5401 00
Universal LED
dimming insert
Komfort, 2-gang
D 190
5402 00
DALI Power
control unit,
flush-mounted
insert
D 193
5406 00
Auxiliary insert,
2-wire
D 194
5408 00
Auxiliary insert,
3-wire
D 194
5409 00
Impulse insert
with staircase
light timer
D 185
5410 00
0821 00
Blind control
insert with
auxiliary input
D 196
5414 00
Blind control
insert without
auxiliary input
D 196
5415 00
Room temperature
controller insert
with sensor
connection
D 197
5395 00
KNX RF operating top unit
D 380
5104 ..
5105 ..
5106 ..
5107 ..
5108 ..
Combination of
KNX RF operating
device and actua-
tor, switching
actuator 1-gang,
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
Combination of
KNX RF operating
device and actua-
tor, temperature
detection,
switching/heating
actuator 1-gang,
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
Combination of
KNX RF operating
device and actua-
tor, switching
actuator 2-gang,
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
Combination of
KNX RF operating
device and actua-
tor, temperature
detection, switch-
ing actuator
1-gang,
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
Combination of
KNX RF operating
device and actua-
tor, dimming
actuator 1-gang,
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
Combination of
KNX RF operating
device and actua-
tor, dimming
actuator 1-gang,
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
Combination of KNX
RF operating device
and actuator,
dimming actuator
2-gang,
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
Combination of KNX
RF operating device
and actuator, tem-
perature detection,
DALI Tunable White
actuator 1-gang
(broadcast),
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
– – –
Combination of KNX
RF operating device
and actuator, tem-
perature detection,
power supply for
operating top units
– – –
Combination of KNX
RF operating device,
temperature
detection, blind
actuator 1-gang,
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
Combination of KNX
RF operating device
and actuator,
temperature
detection, blind
actuator 1-gang,
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
Combination of KNX
RF operating device
and actuator,
temperature
detection, heating
actuator 1-gang,
pushbutton sensor
1-gang/2-gang
independent
of actuator
functionality
Motion detector 1.10 m
Standard
D 202
5373 ..
switching
switching
switching a1 + a2,
switch-on delay
a2, delay time a2
switching
switching
switching
switching
a1 + a2 together
switching
– – –
switching on
switching on
– – –
– – –
– – –
Motion detector 1.10 m
Komfort BT
D 203
5374 ..
switching
app operation
switching
app operation
switching a1 + a2,
switch-on delay
a2, delay time a2,
app operation
switching
app operation
switching
dimming
app operation
switching
dimming
app operation
switching
dimming
a1 + a2 together,
app operation
switching
dimming
app operation
– – –
switching on
switching on
– – –
– – –
– – –
Motion detector 2.20 m
Standard
D 204
5375 ..
switching
switching
switching a1 + a2,
switch-on delay
a2, delay time a2
switching
switching
switching
switching
a1 + a2 together
switching
– – –
switching on
switching on
– – –
– – –
– – –
Motion detector 2.20 m
Komfort BT
D 204
5376 ..
switching
app operation
switching
app operation
switching a1 + a2,
switch-on delay
a2, delay time a2,
app operation
switching
app operation
switching
dimming
app operation
switching
dimming
app operation
switching
dimming
a1 + a2 together,
app operation
switching
dimming
app operation
– – –
switching on
switching on
– – –
– – –
– – –
Presence and motion de-
tector 360° top unit BT
D 205
5377 02
switching
app operation
switching
app operation
switching a1 + a2
switch-on delay
a2, delay time a2,
app operation
switching
app operation
switching
constant lighting
control
app operation
switching
constant lighting
control
app operation
switching
dimming
a1 + a2 together,
constant lighting
control,
app operation
switching
constant lighting
control
app operation
– – –
switching on
switching on
– – –
– – –
– – –
Room temperature control-
ler Display
D 201
5393 ..
heating/cooling
3 time programs
heating/cooling
3 time programs
– – –
heating/cooling
3 time programs
– – –
– – –
– – –
– – –
– – –
– – –
– – –
– – –
– – –
heating/cooling
3 time programs
floor temperature
Room temperature control-
ler BT
D 201
5394 ..
heating/cooling
flexible time
programming
app operation
heating/cooling
flexible time
programming
app operation
– – –
heating/cooling
flexible time
programming
app operation
– – –
– – –
– – –
– – –
– – –
– – –
– – –
– – –
– – –
heating/cooling
flexible time
programming
app operation
floor temperature
The modular system consisting of
power inserts and operating top units
offers the greatest possible freedom in
combining products and implementing
functions. Manual actuation with a
control button is possible alongside
electronic time- or motion-dependent
lighting control.
Central functions can also be
implemented via the auxiliary inputs,
e.g. by means of a wind sensor or a
master button.
In blind and shutter control, auxiliary
units are customarily used for the
higher-level operation of groups and
central control.
In lighting control, the auxiliary units
usually serve as additional control
points or are used to expand the
detection ranges of motion detectors.
In addition, the 3-wire auxiliary insert
enables the central operation of up to
five switching and dimming inserts
(not DALI). It is also possible to combine
timers with motion detectors in the
System 3000.
The eNet wireless operating top units
allow installations from System 3000
to be integrated into the eNet building
network with or without the eNet
server.