192
Gira System 3000
Gira electrical installation systems
System 3000
Inserts, top units
System 3000
The modular system, consisting of
power inserts and operating top units,
offers the greatest possible freedom
in combining products and implementing
functions. Manual actuation with a
control button or electronic time or
motion-dependent lighting control –
the choice is yours.
Central functions can also be
implemented via the auxiliary inputs,
e.g. by means of a wind sensor or a
master button.
For blind and shutter control, auxiliary
units are customarily used for the
higher-level operation of groups and
central control.
For lighting control, the auxiliary units
usually serve as additional operating
points or are used to expand the
detection ranges of motion detectors.
In addition, the 3-wire auxiliary unit
insert enables the central operation of
up to five switching and dimming
inserts (not DALI). It is also possible to
combine timers with motion detectors
in System 3000.
The eNet wireless operating top units
allow installations from System 3000
to be integrated into the eNet building
network with or without the eNet
server.
Lighting control
Lighting control
Blind control
Heating control
Order no.
Relay switching
insert
D 196
5403 00
Relay switching
insert, 2-gang
D 196
5404 00
Electronic
switching insert
D 196
5405 00
Universal LED
dimming insert
Standard
D 198
5400 00
Universal LED
dimming insert
Comfort
D 198
5401 00
Universal LED
dimming insert
Comfort 2-gang
D 198
5402 00
DALI Power
control unit, flush-
mounted insert
D 199
5406 00
Auxiliary unit
insert, 2-wire
D 199
5408 00
Auxiliary unit
insert, 3-wire
D 199
5409 00
Impulse insert
with automatic
staircase lighting
mechanism
D 197
5410 00
0821 00
Blind controller
insert with
auxiliary input
D 200
5414 00
Blind control
insert without
auxiliary unit
input
D 200
5415 00
Room temperature
controller insert
with sensor
connection
D 201
5395 00
Operating top unit
Operating top unit
arrow symbols
D 32, 32
5360 ..
5361 ..
switching
switching a1 + a2,
switch-on delay a2,
delay time a2
switching
switching
dimming
switching
dimming
switching
dimming
a1 + a2 together
switching
dimming
Tunable White
switching
dimming
Tunable White
switching
dimming
Tunable White
switching on
up/down
inscribable position
up/down
inscribable position
– – –
Touch top unit
D 35
5365 ..
switching
switching a1 + a2,
switch-on delay a2,
delay time a2
switching
switching
dimming
sliding
switching
dimming
sliding
switching
dimming
sliding
a1 + a2 together
switching
dimming
sliding
– – –
switching
dimming
sliding
– – –
up/down/sliding
inscribable position
up/down/sliding
inscribable position
– – –
Operating top unit 2-gang
D 32
5362 ..
switching
(left rocker only)
switching a1, a2
separate
switching
(left rocker only)
switching
dimming
(left rocker only)
switching
dimming
(left rocker only)
switching
dimming a1 + a2 sep-
arate
switching
dimming
Tunable White
– – –
switching
dimming
– – –
up/down
inscribable position
(left rocker only)
up/down
inscribable position
(left rocker only)
– – –
eNet operating top unit
Memory arrow symbols
D 32
5363 ..
switching
Memory
switching a1 + a2,
switch-on delay a2,
delay time a2
switching
Memory
switching
dimming
Memory
switching
dimming
Memory
switching
dimming
a1 + a2 together,
Memory
switching
dimming
Memory
– – –
switching
dimming
– – –
up/down
inscribable position
Memory
up/down
inscribable position
Memory
– – –
Blind timer and timer display
D 33
5366 ..
switching
Memory
timer
switching a1 + a2,
switch-on delay a2,
delay time a2
switching
Memory
timer
switching
dimming
Memory
timer
switching
dimming
Memory
timer
switching
dimming
a1 + a2 together,
Memory, timer
switching
dimming
Memory
timer
– – –
switching
dimming
– – –
up/down, position
Memory
blind timer
up/down, position
Memory
blind timer
– – –
Blind timer and timer BT
D 33
5367 ..
switching
timer
app operation
switching a1 + a2,
switch-on delay a2,
delay time a2
switching
timer
app operation
switching
dimming
timer
app operation
switching
dimming
timer
app operation
switching
dimming
a1 + a2 together,
timer,
app operation
switching
dimming
timer
app operation
– – –
switching
dimming
– – –
up/down, position
blind timer
app operation
up/down, position
blind timer
app operation
– – –
eNet wireless operating
top unit
eNet wireless operating
top unit arrow symbols
D 33, 33
5495 ..
5494 ..
switching
eNet
switching a1 + a2,
switch-on delay a2,
delay time a2, eNet
switching
eNet
switching
dimming
eNet
switching
dimming
eNet
switching
dimming
a1 + a2 together,
eNet
switching
dimming
eNet
– – –
switching
dimming
eNet
– – –
up/down
inscribable position
eNet
up/down
inscribable position
eNet
– – –
eNet wireless operating top
unit Memory
eNet wireless operating top
unit Memory arrow symbols
D 33, 33
5493 ..
5492 ..
switching
Memory
eNet
switching a1 + a2,
switch-on delay a2,
delay time a2, eNet
switching
Memory
eNet
switching
dimming
Memory
eNet
switching
dimming
Memory
eNet
switching
dimming
a1 + a2 together,
Memory, eNet
switching
dimming
Memory
eNet
– – –
switching
dimming
eNet
– – –
up/down
inscribable position
Memory, eNet
up/down
inscribable position
Memory, eNet
– – –