Planning example 5 (air extraction) — Metal
VL 200 with AR 403 122 remote fan unit
Island installation, connection from the right side.
List of accessories
— 1 x AR 403 122 (remote fan unit air extraction)
— 1 x AD 858 010 (flat duct flex pipe, metal, DN 150)
— 1 x AD 854 041 (flat duct adapter round, metal, DN 150 flat/round)
— 1 x AD 990 091 (adhesive tape for sealing the ducts, aluminium)
Planning example 4 (air recirculation) — Metal
VL 200 with AR 410 110 remote fan unit
Island installation, access to the filter for replacement from the front or the back.
Good to know
— Allow accessibility to the charcoal filters in the lower cabinet for their
replacement.
— Additionally, if the plinth is higher than 80 mm, the external remote fan unit has
to be elevated to enable access to the filters. If the plinth is 80 mm high, the
remote fan unit can be placed directly on the floor.
— For optimum performance, the recirculated air requires sufficient space to
escape (outflow surface area of at least 400 cm²).
— Please note, this installation is also possible with Gaggenau plastic ducts
List of components
— 1 x AR 410 110 (remote fan unit air recirculation)
— 1 x AD 851 041 (connection piece for extension with flat duct for extra deep
worktop)
— 1 x AD 854 000 (flat duct bend connecting piece, metal, DN 150 flat)
— 1 x AD 854 030 (flat duct bend 90° vertical, metal, DN 150 flat)
— 1 x AD 410 040 (flexibel connecting piece, DN 150 flat)
— 1 x AD 990 091 (adhesive tape for sealing the ducts, aluminium)
Order as set (appliances and accessories): SET1VL2303
List of components — Plastic
— 1 x AR 410 110 (remote fan unit air recirculation)
— 1 x AD 851 041 (connection piece for extension)
— 1 x AD 857 040 (flat duct connecting piece)
— 1 x AD 857 030 (flat duct bend 90° vertical, metal)
— 1 x AD 410 040 (flat flexible connecting piece)
Order as set (appliances and accessories): SET2VL2701
All measurements in mm.
Not recommended for non-thermally insulated floor (U ≥ 0.5 W/m2K)
Surface mounting
Flush mounting (only VL 414)
A:
B:
Measurements in mm
550
670
109
371+X
247
802
213
122
105
40
≥ 80
≥ 50
≤ 50
≥ 80+X
≥ 895+X
≥ 50
492±1
175 (
A
)
178 (
B
)
X
Not recommended for non-thermally insulated floor (U ≥ 0.5 W/m2K)
Surface mounting
Flush mounting (only VL 414)
A:
B:
Measurements in mm
550
670
109
371+X
247
802
213
122
105
40
≥ 80
≥ 50
≤ 50
≥ 80+X
≥ 895+X
≥ 50
492±1
175 (
A
)
178 (
B
)
X
Not recommended for non-thermally insulated floor (U ≥ 0.5 W/m2K)
Surface mounting
Flush mounting (only VL 414)
A:
B:
Measurements in mm
550
670
109
371+X
247
802
213
122
105
40
≥ 80
≥ 50
≤ 50
≥ 80+X
≥ 895+X
≥ 50
492±1
175 (
A
)
178 (
B
)
X