541
BUS DMX
Cod. 186
DMX CONTROLLER
Cod. 142
or
or
Cod. 143
PC + Cod. 143
DMX
OUT
MAINS
Cod. 149
VOUT
48V
LAMP
LAMP
LAMP
Cod. 149
+ -
VOUT
48V
+ -
DMX ID
DMX ID
DMX ID
DMX ID
LAMP
DMX ID
LAMP
DMX ID
LAMP
BUS DMX
Cod. 186
DMX CONTROLLER
Cod. 142
or
or
Cod. 143
PC + Cod. 143
DMX
OUT
MAINS
DMX ID
LAMP
DMX ID
LAMP
DMX ID
LAMP
Wiring Diagram and sample installation n.7
Wiring Diagram and sample installation n.8
ATTENTION
Wiring of LED luminaires run in constant current and connected in series (schemes 1,3 and 5): Never connect the luminaire to a switched on power supply.
Always connect luminaires to the power supply, and only after connect the power supply to the mains.
Connection schemes: Luminaires in constant current must always be connected in series; luminaires in constant tension must always be connected in parallel.
Always respect polarity according to the DC system.
Power Supplies must always match installation features: Never use a constant current power supply on a constant tension luminaire and vice versa.
The choice of the power supply must take into account the real power consumption of the luminaire (data shown in the catalogue) with a 20% increase to face any potential loss on
the installation.
LED Luminaires and power supplies are protected against interferences on the line, it is anyway highly recommended to set dedicated feeding lines to avoid any potential sudden
and severe interference (inductive loads like pumps or discharge lamps) that are likely to damage the LED module.