387
Arcadia
ARCADIA
65
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
A++
A+
A
FLUORESCENT VERSION:
Class A+
T16/G5
A+
EU Regulation 874/2012 - Illumination equipment energy classes
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
.1 White
.6 Grey
.3 Anthracite
.18 Deep Brown
.4 Black
Protection against
impact.
IK 07 - 2,00 joule
Wall fitting
The fitting is equipped
with 1 cable (500mm)
and 1 cable input
Ceiling fitting
• Linear luminaire for installation on wall or ceiling – surface
mounted.
• Configuration: die-cast aluminium closing ends, EN AB-
47100 alloy (low copper content), extruded aluminium
structure and zinc-coated steel fixing brackets. Glass
diffuser: transparent or sandblasted with silkscreen border,
fixed to the aluminium through a robotic gluing system.
• Double layer coating for high resistance to corrosion:
the aluminium components are painted with a double
coat using powders that are compliant with QUALICOAT
standards: a first layer of epoxy powder (with excellent
chemical and mechanical resistance) and a second
finishing layer of polyester powder (resistant to UV rays
and atmospheric agents). The entire painting process of the
aluminium fitting starts from components that have been
sandblasted in advance to make the surface more porous
and increase the adherence of the paint. Ares effects
alkaline and acid washing to clean the surfaces completely,
then rinses with demineralised water to remove any residue
particles, subsequently a chemical conversion treatment is
done to protect against rusting.
• Protection rating: IP65
• In compliance with EN60598-1 standards
• Class of insulation: I; RGB: I
• Installation: the luminaire is equipped with a piece of cable
(approx. 500mm) and an M16 cable-gland (4,5mm<ø<10mm
cables) closed with a removable cap. The electrical
components are installed on a removable frame accessible
by unscrewing the closing ends. Outdoor use requires
suitable flexible cables assuring the watertightness of the
cable holder.
• We recommend the use of a connection system with a
protection degree greater than or equal to the protection
degree of the luminaire.
• During the installation and the maintenance of the fixtures
it is important to be careful and avoid damages on the paint
coating.
Damages on the coating exposed to outdoor conditions or
water, could cause corrosion.
Chemical substances affect the anticorrosion covering
protection.
FLUORESCENT VERSION:
Class A+
T16/G5
.12 Forest Green