171
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
A++
A+
A
Leila
LEILA
66
H2O STOP
EU Regulation 874/2012 - Illumination equipment energy classes
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
• Round luminaire for installation in the ceiling – recessed.
• Configuration: die-cast aluminium structure, EN AB-
47100 alloy (low copper content) and AISI 316L stainless
steel outer frame (raw or painted in white). Glass diffuser:
textured with silkscreen border, fixed to the aluminium
structure through a robotic gluing system.
• Double layer coating for high resistance to corrosion: the
aluminium components are painted with a double coat
using powders which are compliant with QUALICOAT
standards: a first layer of epoxy powder (with excellent
chemical and mechanical resistance) and a second
finishing layer of polyester powder (resistant to UV rays
and atmospheric agents). The entire painting process of the
aluminium fitting starts from components which have been
sandblasted in advance to make the surface more porous
and increase the adherence of the paint. Ares effects
alkaline and acid washing to clean the surfaces completely,
then rinses with demineralised water to remove any residue
particles, subsequently a chemical conversion treatment is
done to protect against rusting.
• Protection rating: IP66
• In compliance with EN60598-1 standards
• Class of insulation: II; version 230V: I
• Installation: the luminaire is equipped with a watertight
M12 screw-connector providing optimal insulation against
water ingress. 220-240V version: the luminaire is supplied
with a remote IP67 electronic power supply kit equipped
with a piece of cable with screw connector towards the
luminaire and a piece of cable to be used for wiring. 230V
direct feeding: the luminaire is equipped with a piece of
cable with a 2-way connector for 3-conductor cables (H2O
STOP) for an easy-to-make connection. Outdoor use requires
suitable flexible cables assuring the watertightness of the
cable gland / connector.
• We recommend the use of a connection system with a
protection degree greater than or equal to the protection
degree of the luminaire.
• During the installation and the maintenance of the fixtures
it is important to be careful and avoid damages on the paint
coating.
Damages on the coating exposed to outdoor conditions or
water, could cause corrosion.
Chemical substances affect the anticorrosion covering
protection.
Pre-wired with
approx 250mm of
cable
Protection against
impact
IK 06 - 1,00 joule (Leila105-135)
IK 07 - 2,00 joule (Leila165-225)
Recessed ceiling
fitting
Protection against
water ingress
from the cable
White
Inox