125
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
A++
A+
A
Chiara
CHIARA
67
kg
H2O STOP
EU Regulation 874/2012 - Illumination equipment energy classes
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
.0 Inox
• Round luminaire for installation on wall or ground –
recessed.
• Configuration: die-cast aluminium structure, EN AB-47100
alloy (low copper content) and AISI 316L blasted stainless
steel frame. Glass diffuser: Sandblasted with silkscreen
border, fixed to the aluminium body through a robotic
gluing system.
• Double layer coating for high resistance to corrosion:
the aluminium components are painted with a double
coat using powders which are compliant with QUALICOAT
standards: a first layer of epoxy powder (with excellent
chemical and mechanical resistance) and a second
finishing layer of polyester powder (resistant to UV rays
and atmospheric agents). The entire painting process of the
aluminium fitting starts from components which have been
sandblasted in advance to make the surface more porous
and increase the adherence of the paint. Ares effects
alkaline and acid washing to clean the surfaces completely,
then rinses with demineralised water to remove any residue
particles, subsequently a chemical conversion treatment is
done to protect against rusting.
• Protection rating: IP67
• In compliance with EN 60598-1 standards
• Class of insulation: mains: I; low-voltage: III
• Installation: the luminaire is equipped with a piece of cable
for an easy-to-make connection. 220-230V version: the
cable is supplied with a 2-way connector for 3-conductor
cables (H2O STOP) for an easy-to-make connection. 24V
version: the cable is integrated with an H2O STOP device.
Outdoor use requires suitable flexible cables. Installation
requires a dedicated box to be ordered separately. It is
important to provide a >200mm gravel layer or a drain
system (for concrete surface) to ensure good drainage and
to avoid water stagnation.
• We recommend the use of a connection system with a
protection degree greater than or equal to the protection
degree of the luminaire.
• During the installation and the maintenance of the fixtures
it is important to be careful and avoid damages on the paint
coating.
Damages on the coating exposed to outdoor conditions or
water, could cause corrosion.
Chemical substances affect the anticorrosion covering
protection.
Installation requires a
20cm water drainage
layer (gravel)
Recessed wall fitting
Glass surface temperature
<70°C
Static load: 500Kg
walk over
Protection against
impact.
IK 08 - 5,00 joule
Pre-wired with approx
250mm of cable.
Remote device
required for 24V
version
Do not install in
hollow areas
Recessed ground fitting
Protection against
water ingress
from the cable