Description
The Ekinex® EK-CA1-TP binary input has 8 independent input channels for connecting
to the KNX bus commands and sensors of traditional type, having potential-free
contacts. Thanks to the binary input, it is possible to command and control bus
functions with standard switches, pushbuttons or sensors (not natively communicating
with the KNX bus) or binary signals made available by other devices. The query voltage
of input channels is produced within the device. The device integrates a KNX bus
communication module and is realized for mounting on a standard 35 mm DIN-rail.
The device is supplied by the KNX bus and does not require auxiliary power supply.
Main features
• Plastic casing
• Frontal programming pushbutton and LED
• Membrane keyboard with LED’s for status indication
• Connection to bus line with KNX terminal block
• Connection of inputs with screw terminals
• Installation on 35 mm rail (according to EN 60715)
• 4 modular units (1 MU = 18 mm)
• IP20 protection degree (installed device)
Technical data
Power supply
• Voltage 30 Vdc by KNX bus
• Current consumption from bus < 13 mA
• Power on bus 320 mW
Inputs
• Number: 8
• Query voltage: < 11 V
• Query current: < 5 mA
Products included
Delivery includes a terminal block for connection to the bus.
Description
The Ekinex® universal interface is a KNX device which can be used as input and/or
output module. The device is equipped with:
• 2 or 4 inputs to connect the KNX bus to switches, pushbuttons or classic sensors
(normally not communicating on the KNX bus) or any binary signals from other
devices, in order to control KNX bus functions;
• 2 or 4 control outputs for low consumption LEDs.
The voltage for polling the inputs is supplied within the device. The device integrates
a KNX bus communication module and is realized for flush-mounting or for mounting
on a standard 35 mm DIN-rail. The device is powered by the KNX bus and does not
require auxiliary power supply.
Main features
• Plastic casing
• Programming pushbutton and LED on the case
• Connection to bus line with KNX terminal block
• Screw terminal blocks for connecting inputs and outputs
• IP20 protection degree (installed device)
Power supply
• 30 Vdc power supply by KNX bus
• Current consumption from bus < 10 mA
Products included
Delivery includes a terminal block for connection to the bus.
Accessories
Support for mounting on a standard 35 mm DIN-rail (code EK-SMG-35) and spring for
snapping on the back of Ekinex® wall-mount devices (code EK-MAR-...) to be ordered
separately.
+
-
KNX
1
2
1A
3
4
2A
5
6
3A
7
8
4A
9
10
1B
11
12
2B
13
14
3B
15
16
4B
1B
2B
3B
4B
1A
2A
3A
4A
EK-CA1-TP
8xD.I. Dry Contacts
bus KNX
1A
2A
3A
4A
9
0
1
1
2
3
4
5
6
7
8
1B
1
1
2
1
2B
3
1
4
1
3B
5
1
6
1
4B
1A
9
0
1
1B
2A
1
1
2
1
2B
3A
3
1
4
1
3B
4A
5
1
6
1
4B
a)
b)
1
2
3
4
5
6
7
8
a) Connection of conventional switches, pushbuttons or presence sensors (on/off)
b) Connection of conventional double pushbuttons (dimming)
+
-
KNX
a)
b)
a) Connection of conventional switches, pushbuttons or presence sensors (on/off)
b) Connection of conventional double pushbuttons (dimming)
Versions
Code
EK-CA1-TP
Documentation
For further details, consult the technical sheet
STEKCA1TP_EN.pdf, available for download from www.ekinex.com
Versions
Code
Inputs / Outputs
EK-CC2-TP
2 IN / 2 OUT
EK-CD2-TP
4 IN / 4 OUT
Documentation
For further details, consult the technical sheet
STEKCCD2TP_EN.pdf, available for download from www.ekinex.com
EK-CC2-TP
EK-CD2-TP
Universal interface
2 (4) IN, 2 (4) OUT
UNIVERSAL INTERFACES
8-fold binary input
INPUTS
SMART LIGHTING
SMART LIGHTING
58
59