deltalight.com
44
1
Ruimte Fluo HE
1.3
Calculation results, Ruimte Fluo HE
1.3.1 Isolines representation, Reference plane 1.1 (E)
Object
Installation
Project number
Date
: Supernova 65 - 95
:
: best travel refter
: 28.06.2016
0
1
2
3
4
5
6
7
8
9[m]
1 : 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
[m]
N
DF1.1
DF1.2
Wi3.1
3
4
5
100
200
200
200
300
300
300
400
400
500
Illuminance [lx]
Height of the reference plane
: 0.75 m
Average illuminance
Eav
: 319 lx
Minimum illuminance
Emin
: 66 lx
Maximum illuminance
Emax
: 573 lx
Uniformity Uo
Emin/Eav
: 1 : 4.81 (0.21)
Diversity Ud
Emin/Emax
: 1 : 8.62 (0.12)
3
Ruimte LED
3.3
Calculation results, Ruimte LED
3.3.1 Isolines representation, Reference plane 1.1 (E)
Object
Installation
Project number
Date
: Supernova 65 - 95
:
: best travel refter
: 28.06.2016
0
1
2
3
4
5
6
7
8
9[m]
1 : 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
[m]
N
DF1.1
DF1.2
Wi3.1
1
3
4
100
200
200
200
300
300
300
400
500
600
700
Illuminance [lx]
Height of the reference plane
: 0.75 m
Average illuminance
Eav
: 384 lx
Minimum illuminance
Emin
: 82 lx
Maximum illuminance
Emax
: 764 lx
Uniformity Uo
Emin/Eav
: 1 : 4.70 (0.21)
Diversity Ud
Emin/Emax
: 1 : 9.34 (0.11)
4
Ruimte LED Line
4.3
Calculation results, Ruimte LED Line
4.3.1 Isolines representation, Reference plane 1.1 (E)
Object
Installation
Project number
Date
: Supernova 65 - 95
:
: best travel refter
: 28.06.2016
0
1
2
3
4
5
6
7
8
9[m]
1 : 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
[m]
N
DF1.1
DF1.2
Wi3.1
1
3
4
100
200
300
300
300
400
400
400
500
600
700
800
900
Illuminance [lx]
Height of the reference plane
: 0.75 m
Average illuminance
Eav
: 500 lx
Minimum illuminance
Emin
: 110 lx
Maximum illuminance
Emax
: 987 lx
Uniformity Uo
Emin/Eav
: 1 : 4.55 (0.22)
Diversity Ud
Emin/Emax
: 1 : 9.00 (0.11)
0
1
2
3
4
5
6
7
8
9[m]
1 : 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
[m]
N
DF1.1
DF1.2
Wi3.1
3
4
5
100
200
200
200
300
300
300
400
400
500
0
1
2
3
4
5
6
7
8
9[m]
1 : 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
[m]
N
DF1.1
DF1.2
Wi3.1
1
3
4
100
200
200
200
300
300
300
400
500
600
700
0
1
2
3
4
5
6
7
8
9[m]
1 : 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
[m]
N
DF1.1
DF1.2
Wi3.1
1
3
4
100
200
300
300
300
400
400
400
500
600
700
800
900
LIGHT
CALCULATION
Area: 39,64 m²
Ceiling Height: 3,00 m
The project study below shows a comparison of
Supernova LED versus T16 fluorescent lamps.
Total power per area 3,03W / m2 / 100lx
Total power per area 1,49W / m2 / 100lx
Total power per area 1,54W / m2 / 100lx
FLOORPLAN
T16 HE
LINE
FULL
SUPERNOVA 65
SUPERNOVA 95