UGR guidelines according DIN EN 12464-1:2011:-08
Type
UGR
Minimum CRI
(Ra)
Offi ce buildings
Reception desks & circulation areas
22
80
Meeting rooms
19
80
(CAD) Workstations
19
80
Technical drawing
16
80
Hospitality
Conference rooms
19
80
Retail
Sales area
22
80
Wrapping
19
90
UGR can help you ensure that your offi ce is optimised
Unifi ed Glare Rating, UGR for short, is an indication of the extent to
which a light source causes glare and light pollution. The higher the
value, the more light pollution there is.
Given the fact that the right lighting has a major impact on people’s
productivity and performance, this rating is very important when
allocating light fi tt ings within a lighting plan.
The deep-set LED module of vektron aplis 60, combined with a variety
of refl ectors, provides this sought-aft er glare-free lighting in diff erent
sett ings.