Do not bend
the cable
IMPORTANT
To ensure a good seal of the IP68 cable gland,
it is important to leave a sufficient length and not
to «bend» the cable just at the exit of the cable
gland.
THE DRAINING
IP68 luminaires:
Drainage is not necessary, but it is important to know that these fixtures are intended to be permanently immersed only in clear water.
They are not designed to be immersed in chlorinated water, seawater or any other aggressive environment.
IP67 luminaires:
To ensure good drainage, install a layer of gravel with a minimum depth of 30cm under the recessed box.
We recommend to perform the following test:
Fill the recessing box with water (Fig.A) and make sure that it has completely dissolved in 30min.
Otherwise, additional drainage is required (Fig.B)
Fig. B
Draining
Fig. A
30 min.
Draining
installation in concrete
waterproof
seal