SPECIFICATIONS
STANDARD COLOURS
00
PURE WHITE
RAL 9016
01
BLACK
RAL 9005
10
WHITE
RAL 9010
24
BRONZE
25
RUST
30
ANTHRACITE
35
SLATE
GREY
40
GREY
RAL 9006
DIMENSIONS
V0
V2
2000kg
Installation:
Ground recessed
• The rated flux values refer to source LED at
Ts85°C / ta25°C
• The Power/Flux in the table refer to maximum
installable value
• Supplied with 3x1mm² cable 300mm long
• Fixing without built-in box
• Walkable for pedestrian paths. Max load
500Kg
• Suitable for dribbling steps. Maximum load
2000Kg
• IP68 connector available on request
CL I
LED SYSTEM WITH BUILT-IN DRIVER - 1 Way
LED SYSTEM WITH BUILT-IN DRIVER - 2 Ways
COD.
Source
Flux
Fixture
Flux
CCT
CRI
Power
CL
4030R/WR2.V0
595 lm
120 lm
3000 K
80
5W - 220-240Vac 50/60Hz
I
4030R/NR2.V0
605 lm
125 lm
4000 K
80
5W - 220-240Vac 50/60Hz
I
COD.
Source
Flux
Fixture
Flux
CCT
CRI
Power
CL
4030R/WR2.V2
1190 lm
250 lm
3000 K
80
9W - 220-240Vac 50/60Hz
I
4030R/NR2.V2
1210 lm
255 lm
4000 K
80
9W - 220-240Vac 50/60Hz
I
Beam
>60°
1 Way Radial Emission
Clear Glass
Not dimmable
(for remote configuration only)
Beam
>60°
2 Ways Radial Emission
Clear Glass
Not dimmable
(for remote configuration only)
CHARACTERISTICS
• Optical system housing accessible during
installation.
• Ground connection system with metal dowels
• Connection to the feeding network through
cable cable gland Max 11mm diameter type
H07RN-F 3x1.5 or similar.
• LED maintenance by opening the optical
compartment.
• Fixed output system with SMD LEDs with
direct 230Vac power supply.
• Luminaire Conforms to EN60598-1 Standard
and special requirements
MATERIALS
• Body: aluminum alloy for extrusion
• Diffusore in Vetro Extra-clear LTF>90%.
• Seals in EDPM closed cell rubber, UV-
resist. Tx -40/+150°C.
• Passive heatsink in aluminum alloy for
extrusion.
• Internal and external screws in A2
Stainless Steel
• Polyester powder coating, UV-stabilised
with anti-corrosion treatment.
ASSEMBLY
103
Ø120
103
Ø120
Ø110
28
150
Ø115
267
GROUND RECESSED