557
H2O STOP
5kN
50Nm
50Nm
kg
SYMBOLS
Glow wire test IEC 60695-2-10: the glow wire test is used to simulate the effect of heat as may arise in
malfunctioning electrical equipment, such as with overloaded or allowing components (specifi ed temperature).
Advice on installation of recessed luminaires:
It is important to provide a consistent gravel layer or drain system to ensure good drainage and to avoid water stagnation.
The luminaire must not be installed in hollow surfaces.
Electric connection:
Wiring through cable input, through two cable inputs or through a feeding transformer installed on remote position (to be ordered
separately).
Luminaire is equipped with 1 or 2 cable input.
Luminaire is equipped with cable and plug.
Protection against water ingress from the cable
Static loxad: Resistance to static load.
In compliance with CEI EN 60598-2-13 standards.
Drive over Resistance to torque and shear loads.
In compliance with CEI EN 60598-2-13 standards.
Dixffuser temperature according to CEI EN 60598-2-13. Check that diffuser’s temperature “T max °C” (tested at 25°C) complies with
your local regulation. Glass surface temperature <70°C for LED source
Surface installation on wall, on ground or on ceiling.
Installation on pole.
In-ground installation (recessed luminaire)
Suspended fi tting.
Resistance to external mechanical impacts:
IK code refers to the maximum external impact the luminaire is capable to withstand, without irreversible damage.
In compliance with EN50102 standards.
IK code
IK00
IK01
IK02
IK03
IK04
IK05
IK06
IK07
IK08
IK09
IK10
Mass/Height
-----
0,2Kg/70mm
0,2Kg/100mm
0,2Kg/175mm
0,2Kg/250mm
0,2Kg/350mm
0,5Kg/200mm
0,5Kg/400mm
1,7Kg/295mm
5,0Kg/200mm
5,0Kg/400mm
Impact Energy
(Joule)
0,00
0,15
0,20
0,35
0,50
0,70
1,00
2,00
5,00
10,00
20,00