227
65
METAL HALIDE VERSION:
Class A+
HIT-TC-CE/G8,5
A+
HALOGEN VERSION:
Class D
QT32/E27
D
EU Regulation 874/2012 - Illumination equipment energy classes
.1 White
.6 Grey
.3 Anthracite
.18 Deep Brown
.4 Black
Bollard Light
Wall fitting
Ceiling fitting
The fitting is
equipped with
1 cable input
Protection against
impact.
IK 07 - 2,00 joule
• Cylindrical light for installation on wall, ceiling and floor or
as a bollard light – surface.
• Configuration: die-cast aluminium structure, EN AB-
47100 alloy (low copper content), extruded aluminium pole
(version �on post�). Borosilicate diffuser: transparent or
sandblasted.
• Double layer coating for high resistance to corrosion:
the aluminium components are painted with a double
coat using powders which are compliant with QUALICOAT
standards: a first layer of epoxy powder (with excellent
chemical and mechanical resistance) and a second
finishing layer of polyester powder (resistant to UV rays
and atmospheric agents). The entire painting process of the
aluminium fitting starts from components which have been
sandblasted in advance to make the surface more porous
and increase the adherence of the paint. Ares effects
alkaline and acid washing to clean the surfaces completely,
then rinses with demineralised water to remove any residue
particles, subsequently a chemical conversion treatment is
done to protect against rusting.
• Protection rating: IP65
• In compliance with EN 60598-1 standards
• Class of insulation: I
• Installation: Mini Silvia: the luminaire is equipped with one
M16 cable gland (4,5<Ø<10mm cables) placed under txhe
head of the luminaire. Mini Silvia on post: the luminaire is
equipped with a piece of cable and a watertight 3-ways
connector (for cables 5<Ø<13mm) for direct or end-to-end
connection. Outdoor use requires suitable flexible cables.
We recommend installation on a concrete basement or
surface, directly with bolts or through the dedicated fixing
plate (to be ordered separately).
• We recommend the use of a connection system with a
protection degree greater than or equal to the protection
degree of the luminaire.
• During the installation and the maintenance of the fixtures
it is important to be careful and avoid damages on the paint
coating.
Damages on the coating exposed to outdoor conditions or
water, could cause corrosion.
Chemical substances affect the anticorrosion covering
protection.
Pre-wired with approx
150mm of cable
METAL HALIDE VERSION:
Class A+
HIT-TC-CE/G8,5
HALOGEN VERSION:
Class D
QT32/E27
MINISILVIA_MINISILVIA ON POST
MiniSilvia - MiniSilvia on post