221
65
New Torcia
NEW TORCIA
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
A++
A+
A
FLUORESCENT VERSION:
Class A
TC-DEL/G24q-2
A
FLUORESCENT VERSION:
Class A
TC-DEL/G24q-3
A
EU Regulation 874/2012 - Illumination equipment energy classes
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
.1 White
.6 Grey
.3 Anthracite
.18 Deep Brown
.4 Black
• Cylindrical light for installation on wall or as a bollard light.
• Configuration: stainless steel top disc, turned aluminium
junction,
extruded
aluminium
pole
and
die-cast
aluminium base, EN AB-47100 alloy (low copper content).
Polycarbonate diffuser: LED: opal; fluorescent: transparent
with metal antiglare louvre.
• Double layer coating for high resistance to corrosion:
the aluminium components are painted with a double
coat using powders which are compliant with QUALICOAT
standards: a first layer of epoxy powder (with excellent
chemical and mechanical resistance) and a second
finishing layer of polyester powder (resistant to UV rays
and atmospheric agents). The entire painting process of the
aluminium fitting starts from components which have been
sandblasted in advance to make the surface more porous
and increase the adherence of the paint. Ares effects
alkaline and acid washing to clean the surfaces completely,
then rinses with demineralised water to remove any residue
particles, subsequently a chemical conversion treatment is
done to protect against rusting.
• Protection rating: IP65
• In compliance with EN 60598-1 standards
• Class of insulation: I
• Installation: the luminaire is equipped with a piece of cable
with a 2-way connector for 3-conductor cables for an easy-
to-make connection. New Torcia LED: direct connection to
the mains. Outdoor use requires suitable flexible cables.
Pole with base: direct fixation with bolts to a concrete
surface or through a dedicated fixing plate (to be ordered
separately) in a concrete basement; Pole in-ground: for a
better stability, we recommend to concrete the root of the
pole.
• We recommend the use of a connection system with a
protection degree greater than or equal to the protection
degree of the luminaire.
• During the installation and the maintenance of the fixtures
it is important to be careful and avoid damages on the paint
coating.
Damages on the coating exposed to outdoor conditions or
water, could cause corrosion.
Chemical substances affect the anticorrosion covering
protection.
Protection against
impact.
IK 09 -10,00 joule
Pre-wired with approx
150mm of cable from
the head.
Connection to be done
inside the pole
Bollard Light
Wall fitting
FLUORESCENT VERSION:
Class A
TC-DEL/G24q-2