191
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
A++
A+
A
Vincenza
VINCENZA
65
67
.1 White
.6 Grey
.3 Anthracite
.18 Deep Brown
.4 Black
EU Regulation 874/2012 - Illumination equipment energy classes
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
• Bollard light.
• Configuration: die-cast aluminium structure, EN AB-47100
alloy (low copper content). Extruded aluminium stem.
Plastic diffuser: sandblasted
• Double layer coating for high resistance to corrosion:
the aluminium components are painted with a double
coat using powders which are compliant with QUALICOAT
standards: a first layer of epoxy powder (with excellent
chemical and mechanical resistance) and a second
finishing layer of polyester powder (resistant to UV rays
and atmospheric agents). The entire painting process of the
aluminium fitting starts from components which have been
sandblasted in advance to make the surface more porous
and increase the adherence of the paint. Ares effects
alkaline and acid washing to clean the surfaces completely,
then rinses with demineralised water to remove any residue
particles, subsequently a chemical conversion treatment is
done to protect against rusting.
• Protection rating: IP65 (with base) or IP67 (in-ground)
• In compliance with EN 60598-1 standards
• Class of insulation: mains: I; low voltage: III
• Installation: version with base: wiring through one M16
cable gland. Direct fixation with bolts to a concrete surface
or through a dedicated fixing plate (to be ordered separately)
in a concrete basement; version in-ground: wiring through
two M16 cable glands. For a better stability, we recommend
to concrete the root of the pole. Outdoor use requires
suitable flexible cables assuring the watertightness of the
cable gland.
• During the installation and the maintenance of the fixtures
it is important to be careful and avoid damages on the paint
coating.
Damages on the coating exposed to outdoor conditions or
water, could cause corrosion.
Chemical substances affect the anticorrosion covering
protection.
Bollard Light�
surface
The fitting is
equipped with
2 cable input for
in-ground version
Remote device required
for low voltage.
Protection against
impact.
IK 10 - 20,00 joule
The fitting is
equipped with
1 cable input for
base version
Do not install in
hollow areas
Bollard Light�in-ground
base.
Installation requires a
30cm water drainage
layer (gravel)
Recessed ground base