131
Clio
CLIO
67
kg
H2O STOP
LED BULB VERSION:
Class A
DRR/GU5,3
A
LED BULB VERSION:
Class A
DR-PAR/GZ10
A
HALOGEN VERSION:
Class B
QR-CBC51/GU5,3
B
HALOGEN VERSION:
Class D
QRPARCBC51/GZ10
D
EU Regulation 874/2012 - Illumination equipment energy classes
.1 White
.6 Grey
.3 Anthracite
.18 Deep Brown
.4 Black
Installation requires a
30cm water drainage
layer (gravel)
Pre-wired with approx
250mm of cable
Remote device required
Check that diffuser’s
temperature “T max °C”
(tested at 25°C)
complies with your
local regulation
Static load: 1000Kg
walk over (Ø 120mm)
Static load: 1500Kg
walk over (Ø 130mm)
Protection against
impact.
IK 09 - 10,00 joule
Protection against
water ingress
from the cable
Do not install in
hollow areas
Recessed ground fitting
• Round luminaire for installation on wall or ground -
recessed.
• Configuration: die-cast aluminium structure, EN AB-
47100 alloy (low copper content) and aluminium or AISI
316L stainless steel frame. Glass diffuser: transparent or
sandblasted.
• Double layer coating for high resistance to corrosion:
the aluminium components are painted with a double
coat using powders which are compliant with QUALICOAT
standards: a first layer of epoxy powder (with excellent
chemical and mechanical resistance) and a second
finishing layer of polyester powder (resistant to UV rays
and atmospheric agents). The entire painting process of the
aluminium fitting starts from components which have been
sandblasted in advance to make the surface more porous
and increase the adherence of the paint. Ares effects
alkaline and acid washing to clean the surfaces completely,
then rinses with demineralised water to remove any residue
particles, subsequently a chemical conversion treatment is
done to protect against rusting.
• Protection rating: IP67
• In compliance with EN 60598-1 standards
• Class of insulation: mains: I; low voltage: III
• Installation: the luminaire is equipped with a piece of cable
with a 2-way connector for 3-conductor cables (H2O STOP)
for an easy-to-make connection. Outdoor use requires
suitable flexible cables. Installation requires a dedicated
box to be ordered separately. It is important to provide
a >300mm gravel layer or a drain system (for concrete
surface) to ensure good drainage and to avoid water
stagnation.
• We recommend the use of a connection system with a
protection degree greater than or equal to the protection
degree of the luminaire.
• During the installation and the maintenance of the fixtures
it is important to be careful and avoid damages on the paint
coating.
Damages on the coating exposed to outdoor conditions or
water, could cause corrosion.
Chemical substances affect the anticorrosion covering
protection.
HALOGEN VERSION:
Class B
QR-CBC51/GU5,3
HALOGEN VERSION:
Class D
QRPARCBC51/GZ10
LED BULB VERSION:
Class A
DRR/GU5,3
DR-PAR/GZ10
.0 Inox