Light distributions
Pleasant, warm
radiance
Melanopic
Response
Radiating from behind the bed, the
wide-angle indirect light component pro-
vides homogeneous ceiling illumination
and a pleasant ambience. The indirect
distribution of light prevents glare for pa-
tients and nursing staff . The warm colour
temperature of 3000 K ensures a posi-
tive atmosphere with consistently good
examination light. Alternatively, the clear-
er, cooler 4000 K colour scheme can be
used as the examination light.
Light and light quality are key factors
for health. The correct lighting creates
an atmosphere that supports patient
recovery and provides nursing staff with
a positive work environment. Using cylin-
drical illuminance, the biological support
eff ect is 371 lx at 3000 K and 299 lx at
4000 K. For those aged over 50, these
values must be increased by 50 %. VITA
MED exceeds this requirement, both for
patients and healthcare workers. VITA
MED also meets the requirement for bio-
logical activation with 75-year-old users,
even taking into account the age-specif-
ic correction factors in accordance with
DIN T/S 5031-100.