[lx]
100
250
750
1000
1500
2000
500
1
2
3
4
5
6
7
25
VITA MED
Examination light (direct 100 % / indirect 100 %)
Visualisation
Number
Luminaires
Light output
2
4
2
Direct module 100 cm / 7200 lm
Indirect module 100 cm / 7200 lm
Indirect module 120 cm / 8640 lm
100 %
100 %
100 %
Measurement area
Standard specifi cation
Em / U0
Light output
Em / U0
General lighting (H = 0.85 m)
Floor
100 - 200 lx
100 - 200 lx / 0.4 - 0.6
1750 lx / 0.7
1400 lx / 0.6
Ceiling
30 - 100 lx / 0.1
1850 lx / 0.7
Walls (ø all walls)
50 - 150 lx / 0.1
≥ 700 lx / 0.6
Level of examination:
basic examination
examination & treatment
300 - 500 lx / 0.6
1000 - 1500 lx / 0.7
2300 lx / 0.65
2300 lx / 0.65
Reading range
300 - 750 lx / 0.7
Standard specifi cation
EZ / U0
2500 lx / 0.9
Light output
EZ / U0
Field of vision patient lying:
for communication:
biologically eff ective for:
50-year-old observer
75-year-old observer
Staff standing (1.6 m):
basic examination
examination & treatment
biologically eff ective
for 50-year-old nursing staff
150 lx / 0.1
technical specifi cation
(DINT/S 67600 / 5031-100)
≥ 450 lx / 0.1
≥ 937 lx / 0.1
100 lx / 0.1
150 lx / 0.1
≥ 450 lx / 0.1
1700 lx / 0.9
1700 lx / 0.9
1700 lx / 0.9
900 lx / 0.7
900 lx / 0.7
900 lx / 0.7
xal.com/vitamed