1220
320
15
38
23
100
1500
1520
320
15
38
23
100
1500
60°
120°
60°
120°
90°
90°
500 lx
400 lx
250 lx
100 lx
TASK 1200 suspended
TASK 1500 suspended
Technical data
DIRECT / INDIRECT POWER
SYS. POWER
COLOUR TEMP.
LUMINOUS FLUX
ORDER CODE
50 W
3000 K
3890 / 2180 lm
0 5 9 - 2 2 2 4
3
K
4000 K
4140 / 2320 lm
52 W
2700 – 6500 K
3620 / 2100 lm
0 5 9 - 2 2 2 4 D 3
K
DIRECT / INDIRECT POWER
SYS. POWER
COLOUR TEMP.
LUMINOUS FLUX
ORDER CODE
63 W
3000 K
4860 / 2720 lm
0 5 9 - 2 2 2 5
3
K
4000 K
5170 / 2900 lm
64 W
2700 – 6500 K
4530 / 2630 lm
0 5 9 - 2 2 2 5 D 3
K
Order options
SUSPENSION
cable 1500 mm
COLOUR TEMPERATURE
3000 K
0
4000 K
1
tunable white 2700 – 6500 K*
*DALI-2 DT8; CRI ≥80
CONTROL
DALI-2
MATERIAL COLOUR
pure white RAL 9010
7
jet black RAL 9005
8
special colours* p. 992
X
*canopy always in white
LIGHT OPTIC COVER
microprismatic (UGR ≤ 19)
Options on request
COLOUR RENDERING INDEX
CRI ≥ 80
CRI ≥ 98 XPECTRUM
CONTROL
ESSENTIAL sensor
(brightness & presence)
TASK 1200 suspended
50 W, 4000 K, direct / indirect power
ROOM VALUES
Room dimensions
5.4 × 4 × 2.8 m
Reflection factor
0.7 | 0.5 | 0.2
Maintenance factor
0.8
Suspension height
2.25 m
CALCULATION SURFACE
Surface dimensions
1.6 × 0.8 m
Surface height
0.75 m
Average illuminance (Em)
> 500 lx
Uniformity (U0)
> 0.6
GLARE EVALUATION
Table Classification X=4H | Y=8H | S=0.25H
UGR transversal
≤ 19
UGR axial
≤ 19
≥ 65° ≤ 3000 cd/m²
UGR
≤ 19
UGR
≤ 19
220-240 V
1 ADDR.
cd/m2
≤ 3000
220-240 V
1 ADDR.
cd/m2
≤ 3000
microprismatic
direct / indirect power
Light distribution
RG 0
IEC 62471
RG 0
IEC 62471
X-PERT
X-PERT
X-PERT
X-PERT
CRI
≥ 90
CRI
≥ 90
xal.com/task
LUMINOUS FLUX value calculated for
CRI ≥90, colour white, cover microprismatic
429