Order options
COLOUR TEMPERATURE
2700 K
4
3000 K
5
4000 K
6
CWD 1800 – 3000 K*
*only for DALI-2
INSET COLOUR
traffic white RAL 9016 (UGR ≤ 22)
7
matt silver (UGR ≤ 19)
4
jet black RAL 9005 (UGR ≤ 16)
1
gold dust RAL 260-M (UGR ≤ 19) 9
BEAM ANGLE
spot 15°
S
medium 21°
M
flood 42°
F
Options on request
COLOR RENDERING INDEX
CRI ≥ 95, 2 SDCM
CONTROL
Casambi
MOUNTING SET
acoustic soft ceilings
POWER SUPPLY
DIM 1 – 10 V
ø 63
48
ø 63
30°
48
ø 63
48
SASSO 60 round
INSET POWER
LUMINOUS FLUX
ORDER CODE
10.7 W 36 Vf 300 mA
1070 lm
0 4 8 - 2 6 0 2
1
10.4 W 35 Vf 300 mA
CWD 949 lm
0 4 8 - 2 6 0 2 E 1
INSET POWER
LUMINOUS FLUX
ORDER CODE
8.2 W 27 Vf 300 mA
635 lm
0 4 8 - 2 6 4 1
1
A
ADJUSTABLE ( IP 40 / IP 20)
DOWNLIGHT ( IP 44 / IP 20)
WALLWASHER (IP 20)
INSET POWER
LUMINOUS FLUX
ORDER CODE
10.7 W 36 Vf 300 mA
1040 lm
0 4 8 - 2 6 2 2
1
10.4 W 35 Vf 300 mA
CWD 949 lm
0 4 8 - 2 6 2 2 E 1
Mounting accessories
TRIMLESS MOUNTING SET for plasterboard ceilings 12.5/15/25 mm
COLOUR
ORDER CODE
traffic white RAL9016
0 4 8 - 2 6 9 6 1 1 7
Light distributions
ø 73
29
73
73
70 × 136
ø 80
40
147
80
21
Electrical accessories
POWER SUPPLY 220-240 V AC, 50-60 Hz,
PC II
TYPE
EFFICIENCY
L·W·H (mm)
ORDER CODE
300 mA | non DIM
η 85 %
85·40·22
0 0 2 - 9 0 7 7 1
300 mA | DALI-2
η 88 %
143·43·30
0 0 2 - 9 0 7 6 2
60
non DIM
60
non DIM
60
non DIM
ø 63
48
INSET POWER
LUMINOUS FLUX
ORDER CODE
8.2 W 27 Vf 300 mA
633 lm
0 4 8 - 2 6 4 1
1
W
WALLWASHER / FLOOR (IP 20)
120
DALI-2
120
DALI-2
120
DALI-2
60
non DIM
120
DALI-2
CRI
≥ 90
UGR
≤ 16
360°
30°
IP 20
IP 44
2-SDCM
wallwasher
wallwasher floor
30°
30°
60°
90°
60°
90°
30°
30°
60°
90°
60°
90°
CRI
≥ 90
1 ADDR.
300 mA
300 mA
CONCRETE MOUNTING HOUSING
COLOUR
L·W·H (mm)
ORDER CODE
exposed concrete ceilings
230·230·162
0 4 8 - 2 6 9 5 2 1 0
primed concrete ceilings*
614·307·120
0 4 8 - 2 6 9 5 1 1 0
*order mounting set separately, not applicable for 2 lamps mounting set with trim
MOUNTING SET WITH TRIM for intermediate ceilings 2–25 mm
TYPE
COLOUR
ORDER CODE
1 lamp
white aluminium RAL 9006
0 4 8 - 2 6 9 6 3 1G
traffic white RAL9016
0 4 8 - 2 6 9 6 3 1 7
jet black RAL 9005
0 4 8 - 2 6 9 6 3 1 8
2 lamps
white aluminium RAL 9006
0 4 8 - 2 6 9 8 3 1G
traffic white RAL9016
0 4 8 - 2 6 9 8 3 1 7
jet black RAL 9005
0 4 8 - 2 6 9 8 3 1 8
INSET POWER is the current
consumption excluding any ballast
LUMINOUS FLUX value calculated for
3000 K, CRI ≥ 90, colour white, flood
2700 K -5 %, 4000 K +5 %
DIN RAIL COMPONENTS
TYPE
W·H·D (mm)
ORDER CODE
POWER SUPPLY 220-240 V AC
96 W | 48V DC constant voltage
90·90·60
0 0 5 - 6 5 2 0 2 1 0
LED DRIVER DALI-2 DT6 1 – 2 addr.
200 – 1050 mA settable const. current
2 × 42W | 48V DC | UOUT 10 – 40 V
36·88·59
0 0 5 - 6 1 2 1 0 3 0
for more details and components see page 981
121
xal.com/sasso
X-PERT
X-PERT