IP68
IP69
IK11
STAINLESS
STEEL V4A
1.4571
316Ti
3.000 K
4.500 K
6.000 K
BLUE
RGB-W
CONSTANT
CURRENT
KONSTANT
STROM
DALI
1-10 V
OPTIONAL
DIMM
CABLE
EXCL.
max 5m
| 71
Monochrome illumination
Dynamic illumination
Retrofit Spotlight | 4.0291
Specifications
LED
white: 12 POW-LED
blue: 48 POW-LED
WATT
white: total 47 W
blue: total 49,5 W
POWER
CC 3600mA @12 V-DC
BEAM
asymmetric Mixflux
CABLE
UW, 2x2,5 qmm
Specifications
LED
12 Multichip POW-LED
WATT
all on 75 W
POWER
CC 1400mA @12 V-DC
BEAM
asymmetric Mixflux
CABLE
UW, 1x4,0 + 4x1,0 +
2x0,25 qmm
Control gear
Details
5.0630.01.12 max 1
5.0630.10.12 max 1
5.0630.11.12 max 1
5.0630.03.12 max 3
➜ 210
Control gear
Details
5.0630.09.52 max 1
➜ 216
Cover
#
Color
Lumen
Standard
4.0291.00.41
RGB-CW cold white 6000K
cold white: 2100 lm
4.0291.00.42
RGB-WW warm white 3000K warm white: 1800 lm
4.0291.00.43
RGB-NW neutral white 4500K neutral white: 1920 lm
Flush Version
4.0291.75.41
RGB-CW cold white 6000K
cold white: 2100 lm
4.0291.75.42
RGB-WW warm white 3000K warm white: 1800 lm
4.0291.75.43
RGB-NW neutral white 4500K neutral white: 1920 lm
Cover
#
Color
Lumen
Standard
4.0291.00.11
6000K cold white
6900 lm
4.0291.00.12
3000K warm white
5640 lm
4.0291.00.13
4500K neutral white
6036 lm
4.0291.00.16
royal blue (450 nm)
500mW/LED
Flush Version
4.0291.75.11
6000K cold white
6900 lm
4.0291.75.12
3000K warm white
5640 lm
4.0291.75.13
4500K neutral white
6036 lm
4.0291.75.16
royal blue (450 nm)
500mW/LED
Notes
· Individual configuration of the LED multichips possible
· Versions with plastic component for retrofit installations available. For wall installation or flexible use on the edge of the pool.
· Spotlights without connected cable for simple retrofitting of halogen to POW LED with use of the existing 2-pin cable (Only monochrome, cross section
min. 2x2.5qmm). The cable can be connected to the connection box without opening the spotlight. Always observe the separate manual instructions.
· In case of retrofitting to RGB-W version, the cable must be replaced with special underwater cable (9.6150.04.41).
· Existing transformers must be replaced by appropriate power supply units and RGBW-controllers.
· Version for saline water see page 72
Underwater environments only