A C 402 181
Stainless steel
Filter module
Air extraction / Air recirculation
Motorless
Installation accessories
A D 754 048
Air collector box DN 150 round pipe
Metal zinc plated
2 x DN 150 round duct air intake.
1 x DN 150 cylindrical duct air outlet.
A D 854 048
Air collector box DN 150 flat duct
Metal zinc plated with plastic
2 x DN 150 flat duct air intake.
1 x DN 150 flat duct air outlet.
Special accessories
A A 010 810
Air recirculation module inclusive
1 activated charcoal filter with high
efficient odour reduction due to
increased surface
Stainless steel
A A 010 811
Air recirculation module inclusive
1 activated charcoal filter.
For air recirculation.
Stainless steel.
A A 012 811
Air recirculation module inclusive
1 activated charcoal filter.
For air recirculation.
White.
A A 200 110
1 activated charcoal filter with high
efficient odour reduction due to
increased surface. For air recirculation
module AA 200 812/816 and
AA 010 811/AA 012 811.
A A 200 112
1 regenerable activated charcoal filter
For air recirculation module
AA 200 812/816 and AA 010 811/
AA 012 811.
Installation accessories for the air
recirculation ducts you will find at the
pages 280 – 292.
Combinable with:
All Vario cooktops 400 series
All Vario cooktops 200 series
All cooktops 400 series
All cooktops 200 series
Good to know:
the hood has to be larger than
the cooktop(s).
Vario ceiling ventilation 400 series
A C 402
–
Discreet integration into the
architecture of the kitchen
–
Flexible by dimension, performance
and ventilation mode
–
Room ventilation
–
Modular ceiling ventilation which
can be configurated individually by
separate components such as filter
module, control modules and light
module
–
Motorless, can be combined with
Gaggenau BLDC remote fan units
–
Highly efficient patented rim
extraction
–
Planed and easy to clean underside
with covered filters
Output
Noise level depends on the built-in
situation.
Features
Rim extraction filter, dishwasher-safe.
Installation frame for thread rods
(threaded rods included in delivery).
Connecting pipe DN 150 round.
Consumption data
Consumption data is referred to a
configuration with the remote fan unit
AR 400 142.
Energy efficiency class B at a range
of energy efficiency classes from
A+++ to D.
Energy consumption 60.6 kWh/year.
Ventilation efficiency class A.
Ilumination efficiency class E.
Grease filter efficiency class B.
Sound level min. 50 dB / max. 65 dB
normal mode.
Planning notes
The ceiling ventilation has to be
handled as a room ventilation when
distance to cooktop is larger than
120 cm since the direct capture of
vapours will be limited. The needed
airflow is given by an air exchange rate
of 10 to 12 times the room volume.
Please refer to page 224 – 225 for
recommended configurations of ceiling
ventilations and remote fan units and
the resulting dimensions.
Refer to the table on page 294 for the
matching remote fan units for air
recirculation or air extraction mode.
For air recirculation an external air
recirculation module is required.
Max. 3 filter modules to be connected
to remote fan unit AR 400 142.
When installing remote fan unit within
the ceiling or furniture block it must
remain accessible through the ceiling
cutout or another maintenance access.
Please ensure when installing the
exhaust air ducting that no sharp
bends are caused and that the
cross-section of the ducting is not
constricted in any way.
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood’s power
supply line needs a suitable safety
switch.
A C 482 181
Stainless steel
Control module with light
A C 462 181
Stainless steel
Control module without light
Vario ceiling ventilation 400 series
A C 482/A C 462
–
Control module of ceiling
ventilation with light
–
Individual integration of light
elements into the configuration of
the ceiling ventilation
Output
Power levels depend on the remote fan
unit, see table on page 300 – 301.
Features
7-key infrared remote control, backup
keys for operation also on the control
module.
3 electronically controlled power levels
and 1 intensive mode.
Interval ventilation, 6 min.
Run-on function, 6 min.
Grease filter saturation indicator.
Planning notes
Connection to the respective
appliances via network cable.
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the power supply line
of the ventilation appliance needs a
suitable safety switch.
Fixing at the filter module.
Connection
Total connected load 355 – 1160 W.
Connecting cable 1.75 m, pluggable.