There is also a boost function, for use when particularly
smelly waste is placed in the waste bin. In this case, Re-
oxide can be forced to activate a purification cycle last-
ing 15 minutes. Pressing the button, without waiting for
the sensor to detect the contamination level on its own,
activates the boost disinfection function.
The LED turns green
and flashes slowly (the colour
gradually fades from bright to pale green).
As soon as the waste bin unit door is closed (the LED
goes out), boost purification starts; if the door is re-
opened before it finishes, the device switches to pause
and the green LED will keep flashing.
If the device still detects contaminants (red LED
)
after a boost cycle, another boost cycle can be started
or the device can be left to operate in automatic mode,
which will remain active until purification is complete.
Refer to the technical manual for all details.
The Reoxide system only functions with the door of the
waste bin base unit closed.
Hold down the on button (the sensor changes colour
from white
to blue
) to activate the device.
When the waste bin base unit door is opened, the LED
comes on, coloured blue
(if the air is clean) or red
(if the air is fouled) depending on the emissions level
recorded by the sensor.
The sensor is coloured blue
if the value measured
inside the waste bin is below the minimum threshold
and will start to turn red as the value rises, becoming
completely red
when the maximum threshold is ex-
ceeded.
Automatic purification now starts (with the waste bin
unit door closed*) to return the values to the minimum
threshold.
If the base unit door is opened during the disinfection
process, Reoxide stops working and the LED comes on,
with the colour appropriate to the current emissions sta-
tus.
The purification process restarts when the door is
closed again, not ending until the air inside the waste
bin is found to be clean.
* When the door is closed, the LED goes out to save energy.
Ernestomeda Spa
Via dell’Economia, 2/8
61025 Montelabbate (PU), Italia
tel. +39 0721 48991
www.ernestomeda.com
Follow us on:
I livelli di emissioni nocive (TVOC) registrati con REOXIDE sono inferiori a 20 μg/
m3, il valore che può essere preso come riferimento dell’aria salubre.
Levels of harmful emissions (TVOC) recorded with REOXIDE are less than 20
μg/m3, the value which can be taken as the benchmark for healthy air.
Senza Reoxide
Without Reoxide
Con Reoxide
With Reoxide
25
20
15
10
5
0
1
8
24
48
ufc/piastra cfu/plate
ore (h) hours (h)
CONTA DEI LIEVITI / YEAST COUNT
25
20
15
10
5
0
1
8
24
48
ore (h) hours (h)
ufc/piastra cfu/plate
CONTA DI MICRORGANISMI A 30° / MICROORGANISM COUNT AT 30°
200
150
100
50
0
1
8
24
48
ore (h) hours (h)
μg/m3 μg/m3
EMISSIONE TOTALE VOC / TOTAL VOC EMISSION
25
20
15
10
5
0
1
8
24
48
ore (h) hours (h)
ufc/piastra cfu/plate
CONTA DI MUFFE / MOULD COUNT