NEW
CODE COMPOSITION
T220 A 000_
finishing
31 W2
white RAL 9010
32 B1
black RAL 9005
example of code
composition
T220 A 00031 W2
CODE COMPOSITION
T220 A 000_
finishing
33 W2
white RAL 9010
34 B1
black RAL 9005
example of code
composition
T220 A 00033 W2
CODE COMPOSITION
T220 A 000_
finishing
39 W2
white RAL 9010
40 B1
black RAL 9005
example of code
composition
T220 A 00039 W2
TECHNICAL FEATURES
Code
T220 A XX
Type
Electrified 90° corner joint for
right-hand turn with internal polarity
and external grounding
Material
Polycarbonate
Finishing
White RAL 9010
Black RAL 9005
Fixing
Plug-in
Insulation class
-
Voltage
connection
16A · 440V, 1A · 50V ac FELV
220-240V · 50/60Hz
Load on phases
max 3.6kVA / 10.8kVA
Note
Electrified 90° angle connector to
insert between two three-phase tracks,
taking care to maintain polarity in the
same position so as to guarantee
electric continuity between the tracks.
Light points cannot be installed
in the corners.
TECHNICAL FEATURES
Code
T220 A XX
Type
Electrified 90° corner joint for left-
hand turn with external polarity and
internal grounding
Material
Polycarbonate
Finishing
White RAL 9010
Black RAL 9005
Fixing
Plug-in
Insulation class
-
Voltage
connection
16A · 440V, 1A · 50V ac FELV
220-240V · 50/60Hz
Carico sulle fasi
max 3.6kVA / 10.8kVA
Note
Electrified 90° angle connector to
insert between two three-phase tracks,
taking care to maintain polarity in the
same position so as to guarantee
electric continuity between the tracks.
Light points cannot be installed
in the corners.
TECHNICAL FEATURES
Code
T220 A XX
Type
Electrified “X” connector
Material
Polycarbonate
Finishing
White RAL 9010
Black RAL 9005
Fixing
Plug-in
Insulation class
-
Voltage
connection
16A · 440V, 1A · 50V ac FELV
220-240V · 50/60Hz
Load on phases
Max 3.6kVA / 10.8kVA
Note
Electrified “X” connector between four
three-phase perpendicular tracks to
be positioned taking care to maintain
polarity in the same position so as to
guarantee electric continuity between
the tracks.
Light points cannot be installed
in the corners.
GIUNTO ANGOLARE A 90°
PER CURVA A DESTRA
90° CORNER JOINT
FOR RIGHT TURN
GIUNTO ANGOLARE A 90°
PER CURVA A SINISTRA
90° CORNER JOINT
FOR LEFT TURN
GIUNTO A “X”
“X” CONNECTOR
The tracks and their components must be installed following the installation instructions provided by the company.
All Buzzi & Buzzi power supply accessories are designed for right hand polarity.
www.buzzi-buzzi.it | 147
Indoor 220V Tracks
www.buzzi-buzzi.it | 147
Indoor 220V Tracks