Working Catalogue
www.formalighting.com
96
97
- Track
Zero Compasso 66 Wallwasher
Zero Compasso 100 Wallwasher
• Distance from wall (y): 1m
• Disteance between fixtures (x): 1.1m
• Distance from wall (y): 1m
• Disteance between fixtures (x): 0.83m
Example of a wallwasher table
Illuminances 1x (Wall)
Angle of tilt (
)
10O
Wall Height (m)
3
Wall Width (m)
7
Offset from Wall (m) y
1.00
1.25
1.50
1.50
Luminaire spacing (m) x
0.83
1.00
1.25
1.50
Illuminance (lx) Average
141
117
105
78
Illuminance (lx) Max
242
201
180
134
Example of a wallwasher table
Illuminances 1x (Wall)
Angle of tilt (
)
0O
Wall Height (m)
4
Wall Width (m)
7
Offset from Wall (m) y
1.00
1.25
1.50
1.50
Luminaire spacing (m) x
1.00
1.25
1.50
1.50
Illuminance (lx) Average
126
105
93
70
Illuminance (lx) Max
223
186
165
124
y
x
y
x
Luminaire spacing
The luminaire spacing (x) for some wallwashers can vary by up to
1.5 times the wall offset (y). Corresponding details are provided in
the wallwasher table in catalog datasheets. Computerized beam
calculations are recommended to check potential intersections
with side walls.
Wallwasher angle of tilt
The lens wallwasher requires tilting. The product data sheet
specifies the optimal tilt angle ( ) for uniform light distribution on
the wall.
Luminaire spacing
The luminaire spacing (x) for some wallwashers can vary by up to
1.5 times the wall offset (y). Corresponding details are provided in
the wallwasher table in catalog datasheets. Computerized beam
calculations are recommended to check potential intersections
with side walls.
Wallwasher angle of tilt
The lens wallwasher requires tilting. The product data sheet
specifies the optimal tilt angle ( ) for uniform light distribution on
the wall.
Lighting Effects
Lighting Effects
y
y