102
For further informa� on, please visit / Per ulteriori informazioni visita www.castaldiligh� ng.it
D66 EMC2
outdoor - esterni
Prdouct Plus
Plus di prodotti
D������ �����
D������� ����� ����
The dynamic lighting system is controlled by radiofrequencies. The software (APP) allows to set the data to manage the
luminous flux (where, how, etc..) in order to avoid energy loss.
The amount of flux remains set to the minimum value and increases only when the motion sensor detects users
movements. Compared to traditional flux reduction solutions, this dynamic control allows major savings, high efficiency
and maximum road safety during any traffic conditions.
Nel sistema ad illuminazione dinamica il controllo avviene in radiofrequenza. Il software (APP) permette di impostare
i dati per gestire il flusso luminoso (dove, quanto, etc…) in modo da evitare sprechi.
La quantità di �usso rimane impostata sul valore minimo e aumenta solo quando il sensore di movimento intercetta il
passaggio di utenti. Rispetto alle soluzioni tradizionali di riduzione del flusso luminoso, questo controllo dinamico consente
maggiori risparmi, elevata efficienza e massima sicurezza stradale in funzione delle condizioni di traffico.
�������������������
����������������
media dei consumi
������������������
�������������������
�������������������
media dei consumi
���������������������
����������������
��������������
consumi con
�����������������
����������������
�����������
consumi con
��������������
% energy
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
18
19
20
21
22
23
00
01
02
03
04
05
06
07
08
hour
Low traffic street
- Flux reduction:
30% consumption savings compared
to its full power (graphic blue)
- Dynamic flux control: 70% consumption
savings compared to its full power
(graphic red).
Strada poco trafficata
- Riduzione del �usso:
risparmio sui consumi del 30% rispetto
alla piena potenza (grafico blu).
- Controllo dinamico del �usso:
risparmio sui consumi del 70% rispetto
alla piena potenza (grafico rosso).
% energy
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
18
19
20
21
22
23
00
01
02
03
04
05
06
07
08
hour
Congested traffic street
- Flux reduction:
30% consumption savings compared
to its full power (graphic blue).
- Dynamic flux control: 50% consumption
savings compared to its full power
(graphic red).
Strada molto trafficata
- Riduzione del �usso:
risparmio sui consumi del 30% rispetto
alla piena potenza (grafico blu).
- Controllo dinamico del �usso:
risparmio sui consumi del 50% rispetto
alla piena potenza (grafico rosso).