26
Luminaire guide video
Ghost for breeze block application is
easily applied in walls made of perforated
bricks or cement conglomerate.
The luminaire is designed to be wall
mounted and completely integrated with
the architecture of which it will take over
the finish.
The cavity is pre-finished and ready for
painting.
The procedure is as follows:
1. Plan the positioning of the corrugated
tube for mains electrical connection;
2. Make a niche to insert the Ghost
polystyrene block, paying attention
to its aligning;
3. Lay the fixative grid that connects the
cement conglomerate wall to the Ghost’s
polystyrene block;
4. Enclose the luminaire in the wall, cut
the grid at the Ghost’s cavity and finish
off;
5. Once the work is finished, the
luminaire may be installed.
Protection class
IP65
Mechanical resistance
IK 10
Leds 4000K CRI80 versions are available
on request.
24V DC versions available with surcharge
for use with remote dimmable drivers not
included.
PATENT PENDING
REGISTERED DESIGN
MICROGHOST SQUARE
Requires a remote constant voltage driver.
Pre-wired luminaire with 6m of neoprene cable.
CLASS III
GHOST HORIZONTAL
Pre-wired luminaire with 0,3m neoprene cable
and connector in the recessed box.
CLASS I y
For the latest technical information
and luminaire updates with LED
technology please refer to
www.simes.it
Example 1
WALL IN CLAY
BLOCKS
Example 2
WALL IN BREEZE
BLOCKS
Ghost for construction materials with plaster finish