TESTING LABORATORY
All testing activities are supervised once a year by the Official Certification Bodies (IMQ S.p.A. and UL).
The laboratories are recognized by IMQ and VDE according to the CTFs STAGE 2 (Customers’ Testing Facilities) procedures
that release the ENEC label in compliance with the following standards:
IEC/EN 60598-1
Luminaires
IEC/EN 60598-2-1
Luminaires - Part 2-1: Particular requirements – Specification for fixed general purpose luminaires
IEC/EN 60598-2-2
Luminaires - Part 2-2: Particular requirements – Recessed luminaires
IEC/EN 60598-2-3
Luminaires - Part 2-3: Particular requirements –Luminaires for road and street lighting
IEC/EN 60598-2-4
Luminaires - Part 2-4: Particular requirements – Portable general purpose luminaires
IEC/EN 60598-2-5
Luminaires - Part 2-5: Floodlights
IEC/EN 60598-2-7
Luminaires - Part 2-7: Particular requirements – Portable luminaires for garden use
IEC/EN 60598-2-13
Luminaires - Part 2-13: Particular requirements - Ground recessed luminaires
IEC/EN 6598-2-18
Luminaires - Part 2-18: Particular requirements – Luminaries for swimming pools and similar applications
IEC/EN 62031
LED modules for general lighting - Safety specifications
Furthermore, the laboratories are recognized by UL according to the WTDP (Witness Test Data Program) for the release of the
UL label in compliance with the following standards:
UL 1598
Luminaires
CSA C22.2 NO 250.0-08
Luminaires
UL 8750
Standard for Light Emitting Diode (LED) Equipment for Use in Lighting Products
CSA C22.2 NO 250.13-12
Light Emitting Diode (LED) Equipment for Lighting Applications
The laboratories also include a specific room (equipped with the best EMI Receivers available) to measure the electromagnetic
disturbances (EMC). The equipment checks whether the products are complying with the most important related standards
which ones are:
CISPR 15
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
EN 55015
European Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
IEC EN 61000-3-2
Electromagnetic compatibility (EMC) - Part 3-2 - Limits - Limits for harmonic current emissions
XLI