MasterCool
Planning notes
2. Air vents in the plinth ensure ventilation of the appliances. The air vents above the plinth panel must not be covered or obstructed.
The plinth panel has a height of 102 mm and should be at least 13 mm thick (19 mm recommended). The plinth return should be at
least 71.7 mm to ensure sufficient air circulation. More detailed diagrams can be found in the installation drawings for each
appliance.
3. Mains water connection: the water pressure must be between 2 and 8.25 bar.
The stainless steel hose is 2 m long.
4. A stopcock must be provided between the stainless steel hose and the household water supply to ensure that the water supply
can be cut off if necessary.
5. The surrounding walls of the installation niche must be at least 16 mm thick.
6. MasterCool sample dimensions
= KSK 2001 Side-by-Side installation kit including side panel heater already installed
= Plinth 102–132 mm
(height-adjustable by up to 30 mm)
= Total niche width 1220 mm (458 mm + 762 mm)